Please use this identifier to cite or link to this item:
http://doi.org/10.25358/openscience-7038
Authors: | Niebler, Stefan Schömer, Elmar Tjaden, Henning Schwanecke, Ulrich Schulze, Ralf |
Title: | Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data |
Online publication date: | 25-May-2022 |
Year of first publication: | 2019 |
Language: | english |
Abstract: | Purpose Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to develop a marker-free iterative motion correction algorithm that works on the projection images and is suitable for local tomography. Methods We present an iterative motion correction algorithm that allows the patient's motion to be detected and taken into account during reconstruction. The core of our method is a fast GPU-accelerated three-dimensional reconstruction algorithm. Assuming rigid motion, motion correction is performed by minimizing a pixel-wise cost function between all captured x-ray images and parameterized projections of the reconstructed volume. Results Our method is marker-free and requires only projection images. Furthermore, it can deal with local tomography data. We demonstrate the effectiveness of our approach on both simulated and real motion-beset patient images. The results show that our new motion correction algorithm leads to accurate reconstructions with sharper edges, better contrasts and more detail. Conclusions The presented method allows for correction of patient motion with observable improvements in image quality compared to uncorrected reconstructions. Potentially, this may reduce the number of retakes caused by corrupted reconstructions due to patient movements. |
DDC: | 004 Informatik 004 Data processing |
Institution: | Johannes Gutenberg-Universität Mainz |
Department: | FB 08 Physik, Mathematik u. Informatik |
Place: | Mainz |
ROR: | https://ror.org/023b0x485 |
DOI: | http://doi.org/10.25358/openscience-7038 |
Version: | Published version |
Publication type: | Zeitschriftenaufsatz |
Document type specification: | Scientific article |
License: | CC BY |
Information on rights of use: | https://creativecommons.org/licenses/by/4.0/ |
Journal: | Medical physics 46 10 |
Pages or article number: | 4470 4480 |
Publisher: | Wiley |
Publisher place: | Hoboken, NJ |
Issue date: | 2019 |
ISSN: | 2473-4209 1522-8541 0094-2405 |
Publisher DOI: | 10.1002/mp.13731 |
Appears in collections: | JGU-Publikationen |
Files in This Item:
File | Description | Size | Format | ||
---|---|---|---|---|---|
projectionbased_improvement_o-20220525114531380.pdf | 581.38 kB | Adobe PDF | View/Open |