Variability of transient elastography-based spleen stiffness performed at 100 Hz

dc.contributor.authorArmandi, Angelo
dc.contributor.authorMerizian, Talal
dc.contributor.authorWerner, Merle Marie
dc.contributor.authorCoxson, Harvey O.
dc.contributor.authorSanavia, Tiziana
dc.contributor.authorBirolo, Giovanni
dc.contributor.authorGashaw, Isabella
dc.contributor.authorErtle, Judith
dc.contributor.authorMichel, Maurice
dc.contributor.authorGalle, Peter R.
dc.contributor.authorLabenz, Christian
dc.contributor.authorEmrich, Tilman
dc.contributor.authorSchattenberg, Jörn M.
dc.date.accessioned2024-01-16T09:48:44Z
dc.date.available2024-01-16T09:48:44Z
dc.date.issued2023
dc.description.abstractBackground Spleen stiffness measurement (SSM) performed by transient elastography at 100 Hz is a novel technology for the evaluation of portal hypertension in advanced chronic liver disease, but technical aspects are lacking. We aimed to evaluate the intraexamination variability of SSM and to determine the best transient elastography protocol for obtaining robust measurements to be used in clinical practice. Methods We analyzed 253 SSM exams with up to 20 scans for each examination, performed between April 2021 and June 2022. All SSM results were evaluated according to different protocols by dividing data into groups of n measurements (from 2 to 19). Considering as reference the median SSM values across all the 20 measurements, we calculated the distribution of the absolute deviations of each protocol from the reference median. This analysis was repeated 1,000 times by resampling the data. Distributions were also stratified by etiology (chronic liver disease versus clinically significant portal hypertension) and different SSM ranges: < 25 kPa, 25–75, and > 75 kPa. Results Overall, we observed that the spleen stiffness exam had less variability if it exceeded 12 measurements, i.e., absolute deviations ≤ 5 kPa at 95% confidence. For exams with higher SSM values (> 75 kPa), as seen in clinically significant portal hypertension, at least 15 measurements are highly recommendable. Conclusions Fifteen scans per examination should be considered for each SSM exam performed at 100 Hz to achieve a low intraexamination variability within a reasonable time in clinical practice.en_GB
dc.identifier.doihttp://doi.org/10.25358/openscience-9916
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/9934
dc.language.isoeng
dc.rightsCC-BY-4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleVariability of transient elastography-based spleen stiffness performed at 100 Hzen_GB
dc.typeZeitschriftenaufsatzde_DE
jgu.apc.netprice1315,60
jgu.apc.price1565,56
jgu.apc.taxrate19
jgu.apc.transformationcontractSpringer (DEAL)
jgu.dfg.year2023
jgu.journal.titleEuropean radiology experimental
jgu.journal.volume7
jgu.nationalcurrency.eur1315,60
jgu.organisation.departmentFB 04 Medizinde_DE
jgu.organisation.nameJohannes Gutenberg-Universität Mainzde_DE
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative79
jgu.publisher.doi10.1186/s41747-023-00393-2
jgu.publisher.issn2509-9280
jgu.publisher.nameSpringer International Publishing
jgu.publisher.placeDordrecht u.a.
jgu.publisher.year2023
jgu.rights.accessrightsopenAccessen_GB
jgu.subject.ddccode610
jgu.subject.dfgLebenswissenschaftende_DE
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTexten_GB
jgu.type.versionPublished versionen_GB

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
variability_of_transient_elas-20240116103831389.pdf
Size:
1.85 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections