Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-9378
Authors: Dagher, Sarah
Ishiyama, Shimpei
Title: Protocol for precise signal synchronization of electrophysiology, videography, and audio recordings using a custom-made pulse generator
Online publication date: 17-Aug-2023
Year of first publication: 2023
Language: english
Abstract: Precise signal synchronization is vital for accurate analysis in systems neuroscience. Here, we present a protocol for synchronizing electrophysiology, videography, and audio recordings using a custom-made pulse generator. We describe steps for building the pulse generator, installing software, connecting devices, and running experimental sessions. We then detail signal analysis, temporal alignment, and duration normalization. This protocol offers flexibility and cost-effectiveness, addressing limited shared knowledge and providing a solution for signal synchronization in various experimental setups.
DDC: 610 Medizin
610 Medical sciences
Institution: Johannes Gutenberg-Universität Mainz
Department: FB 04 Medizin
Place: Mainz
ROR: https://ror.org/023b0x485
DOI: http://doi.org/10.25358/openscience-9378
Version: Published version
Publication type: Zeitschriftenaufsatz
Document type specification: Scientific article
License: CC BY
Information on rights of use: https://creativecommons.org/licenses/by/4.0/
Journal: STAR Protocols
4
2
Pages or article number: 102306
Publisher: Elsevier
Publisher place: Amsterdam
Issue date: 2023
ISSN: 2666-1667
Publisher DOI: 10.1016/j.xpro.2023.102306