Pediatric craniospinal irradiation with a short partial-arc VMAT technique for medulloblastoma tumors in dosimetric comparison

dc.contributor.authorPollul, Gerhard
dc.contributor.authorBostel, Tilman
dc.contributor.authorGrossmann, Sascha
dc.contributor.authorAkbaba, Sati
dc.contributor.authorKarle, Heiko
dc.contributor.authorStockinger, Marcus
dc.contributor.authorSchmidberger, Heinz
dc.date.accessioned2021-04-27T10:23:49Z
dc.date.available2021-04-27T10:23:49Z
dc.date.issued2020
dc.description.abstractBACKGROUND This study aimed to contrast four different irradiation methods for pediatric medulloblastoma tumors in a dosimetric comparison regarding planning target volume (PTV) coverage and sparing of organs at risk (OARs). METHODS In sum 24 treatment plans for 6 pediatric patients were realized. Besides the clinical standard of a 3D-conformal radiotherapy (3D-CRT) treatment plan taken as a reference, volumetric modulated arc therapy (VMAT) treatment plans (“VMAT_AVD” vs. “noAVD” vs. “FullArc”) were optimized and calculated for each patient. For the thoracic and abdominal region, the short partial-arc VMAT_AVD technique uses an arc setup with reduced arc-length by 100°, using posterior and lateral beam entries. The noAVD uses a half 180° (posterior to lateral directions) and the FullArc uses a full 360° arc setup arrangement. The prescription dose was set to 35.2 Gy. RESULTS We identified a more conformal dose coverage for PTVs and a better sparing of OARs with used VMAT methods. For VMAT_AVD mean dose reductions in organs at risk can be realized, from 16 to 6.6 Gy, from 27.1 to 8.7 Gy and from 8.0 to 1.9 Gy for the heart, the thyroid and the gonads respectively, compared to the 3D-CRT treatment method. In addition we have found out a superiority of VMAT_AVD compared to the noAVD and FullArc trials with lower exposure to low-dose radiation to the lungs and breasts. CONCLUSIONS With the short partial-arc VMAT_AVD technique, dose exposures to radiosensitive OARS like the heart, the thyroid or the gonads can be reduced and therefore, maybe the occurrence of late sequelae is less likely. Furthermore the PTV conformity is increased. The advantages of the VMAT_AVD have to be weighed against the potentially risks induced by an increased low dose exposure compared to the 3D-CRT method.en_GB
dc.identifier.doihttp://doi.org/10.25358/openscience-5847
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/5856
dc.language.isoeng
dc.rightsCC-BY-4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titlePediatric craniospinal irradiation with a short partial-arc VMAT technique for medulloblastoma tumors in dosimetric comparisonen_GB
dc.typeZeitschriftenaufsatzde_DE
jgu.apc.price1736,00
jgu.journal.titleRadiation oncology
jgu.journal.volume15
jgu.organisation.departmentFB 04 Medizinde_DE
jgu.organisation.nameJohannes Gutenberg-Universität Mainzde_DE
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative256
jgu.publisher.doi10.1186/s13014-020-01690-5
jgu.publisher.issn1748-717X
jgu.publisher.nameBioMed Central
jgu.publisher.placeLondon
jgu.publisher.urihttps://doi.org/10.1186/s13014-020-01690-5
jgu.publisher.year2020
jgu.rights.accessrightsopenAccessen_GB
jgu.subject.ddccode610
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTexten_GB
jgu.type.versionPublished versionen_GB

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
pollu_gerhard-pediatric_cran-20210427121517136.pdf
Size:
1.04 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description: