Retention forces in mini-dental-implant retained mandibular overdentures : 10-year outcomes of a non-comparative longitudinal observational study

dc.contributor.authorBukvic, Hristina
dc.contributor.authorSchenk, Nicole
dc.contributor.authorHinz, Sebastian
dc.contributor.authorSchimmel, Martin
dc.contributor.authorEnkling, Norbert
dc.contributor.authorAbou‑Ayash, Samir
dc.date.accessioned2025-09-24T06:13:08Z
dc.date.issued2025
dc.description.abstractPurpose To report the evaluation of in vivo retention forces after replacement of O-rings in one-piece mini dental implants (MDIs), retaining mandibular implant overdentures (IODs) with ball/O-ring attachments during 10 years assessed. Methods Twenty patients received new complete dentures, which were converted into IODs through stabilization with four MDIs (Condent GmbH; diameter: 1.8 mm) placed in the interforaminal region. Retention forces were measured at the male and female parts at baseline, 5, and 10 years using a validated strain gauge. Fourteen patients completed the 10-year follow-up. Results After 10 years, a minor but significant reduction in retention force was observed in the male part of the implant at position 44. In contrast, neither the male part at the other implant positions nor the female part at any position showed a significant decrease in retention force compared to baseline. After replacement of the O-ring inserts, baseline values could be restored and no significant changes in retention forces were observed at the 10-year follow-up. No difference in anterior and posterior implants could be determined. Conclusions Initial retention forces of mandibular IODs supported by four MDIs can be reestablished by replacing the O-rings with pristine ones after 10 years, with stable retention forces at both the male and female parts throughout the functional period, with no discernible differences between anterior and posterior implants.en_GB
dc.identifier.doihttps://doi.org/10.25358/openscience-13359
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/13380
dc.language.isoeng
dc.rightsCC-BY-4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleRetention forces in mini-dental-implant retained mandibular overdentures : 10-year outcomes of a non-comparative longitudinal observational studyen_GB
dc.typeZeitschriftenaufsatzde_DE
jgu.apc.netprice1942,46
jgu.apc.price2078,43
jgu.apc.taxrate7
jgu.apc.transformationcontractSpringer (DEAL)
jgu.dfg.year2025
jgu.journal.titleInternational journal of implant dentistry
jgu.journal.volume11
jgu.nationalcurrency.eur1942,46
jgu.organisation.departmentFB 04 Medizinde_DE
jgu.organisation.nameJohannes Gutenberg-Universität Mainzde_DE
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative32
jgu.publisher.doi10.1186/s40729-025-00620-y
jgu.publisher.eissn2198-4034
jgu.publisher.nameSpringer
jgu.publisher.placeBerlin, Heidelberg
jgu.publisher.year2025
jgu.rights.accessrightsopenAccessen_GB
jgu.subject.ddccode610
jgu.subject.dfgLebenswissenschaftende_DE
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTexten_GB
jgu.type.versionPublished versionen_GB

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
retention_forces_in_minidenta-20250924081308629346.pdf
Size:
1,012.27 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
5.14 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections