Optical analysis of the behavior of sealants under mechanical, thermal and chemical stress

dc.contributor.authorErbe, Christina
dc.contributor.authorDeckers, Florian
dc.contributor.authorSchmidtmann, Irene
dc.contributor.authorHeider, Julia
dc.contributor.authorWehrbein, Heinrich
dc.date.accessioned2022-04-11T09:28:57Z
dc.date.available2022-04-11T09:28:57Z
dc.date.issued2021
dc.description.abstractRegarding their resistance five sealants were tested in vitro after experiencing mechanical, thermal and chemical stress. Included for testing were two fluoride varnishes: Fluor Protector [FP] (Ivoclar Vivadent) and Protecto CaF2 Nano One-Step Seal [PN] (BonaDent) and three fluoride-composite filled sealants (with acid etch technique): Clinpro XT Varnish [CP] (3 M Espe), Pro Seal [PS] & Light Bond [LB] (Reliance Orthodontic Products) and a positive control group [CG] Tetric EvoFlow (Ivoclar Vivadent). The sealants were applied on 180 bovine teeth (n = 10/ sealer) in a standardized manner after bracket bonding. Mechanical pressure and its effect by simulating different time points and standardized electric cleaning protocol was tested first. Followed by thermal burden due to varying thermal stress and thirdly change in pH stress imitating chemical exposure were examined separately. A digital microscope and a grid incisal and apical to the brackets (n = 32 fields) was used to standardize the optical analysis. Material loss due to mechanical stress compared to CG (score 0.00) was CP (1.2%), FP (21.5%), LB (22.2%) and PN (81.1%). No significant difference to CG presented PS. Material loss due to thermal stress was CP (0.5%), PS (2%), FP (2.6%), LB (3.1%) and PN (39.9%). Material loss due to chemical stress was FP (1.8%), PS (2.1%), LB (5.5%) and PN (39.6%). No significant difference to CG presented CP. Only PS and CP had optically provable, good resiliance to mechanical, thermal and chemical stress. Significantly poorer outcomes in particular showed PN.en_GB
dc.identifier.doihttp://doi.org/10.25358/openscience-6878
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/6889
dc.language.isoeng
dc.rightsCC-BY-4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleOptical analysis of the behavior of sealants under mechanical, thermal and chemical stressen_GB
dc.typeZeitschriftenaufsatzde_DE
jgu.apc.price1837,00
jgu.journal.titleScientific reports
jgu.journal.volume11
jgu.organisation.departmentFB 04 Medizinde_DE
jgu.organisation.nameJohannes Gutenberg-UniversitƤt Mainzde_DE
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative7655
jgu.publisher.doi10.1038/s41598-021-87288-7
jgu.publisher.issn2045-2322
jgu.publisher.nameNature Publishing Group
jgu.publisher.placeLondon
jgu.publisher.year2021
jgu.rights.accessrightsopenAccessen_GB
jgu.subject.ddccode610
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTexten_GB
jgu.type.versionPublished versionen_GB

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
optical_analysis_of_the_behav-20220411112553824.pdf
Size:
1.81 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description: