Influence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns : an in-vitro study

dc.contributor.authorGörgen, Carolin-Isabel
dc.contributor.authorSagheb, Kawe
dc.contributor.authorLehmann, Karl Martin
dc.contributor.authorSchmidtmann, Irene
dc.contributor.authorWentaschek, Stefan
dc.date.accessioned2023-08-23T11:00:07Z
dc.date.available2023-08-23T11:00:07Z
dc.date.issued2023
dc.description.abstractBackground In implant prosthetic dentistry, the adhesive connection of individualized ceramic crowns and prefabricated titanium bases leads to several benefits. However, the durability of the bonding could be a weak point and especially depends on sufficient surface pretreatment. Cold atmospheric-pressure plasma (CAP) is a pretreatment method that should improve the surface properties without physical damage. Thus, the purpose of this study was to investigate the influence of CAP treatment on pull-off tensile load in two-piece abutment crowns. Methods Eighty zirconia crowns and titanium bases were divided into eight groups (n = 10) according to their surface pretreatment prior to cementation with Panavia V5: no treatment (A); sandblasting (B); 10-MDP primer (C); sandblasting and primer (D); CAP (AP); sandblasting and CAP (BP); CAP and primer (CP); sandblasting, CAP and primer (DP). The specimens were thermocycled (5°/55°, 5000 cycles), and then the pull-off tensile load (TL) was measured. Statistical analyses were performed using three-way ANOVA with Tukey post-hoc and Fisher’s exact tests. Results The results showed that the TL was highest in group D (p < 0.0001). Some combinations of different treatments led to effects that were greater than the sum of the individual effects. These effects were modified by interactions. Only in combination with primer, CAP treatment had a small but positive significant effect (group CP vs. C and CP vs. AP, p < 0.0001) which however did not come close to the strong interaction effect that resulted from the combination of sandblasting and primer. Conclusion Within the limitations of this study, CAP treatment cannot be recommended in this specific field of indication due to its unreliable influence on TL in combination with other pretreatment methods.en_GB
dc.description.sponsorshipDeutsche Forschungsgemeinschaft (DFG)|491381577|Open-Access-Publikationskosten 2022–2024 Universität Mainz - Universitätsmedizin
dc.identifier.doihttp://doi.org/10.25358/openscience-9434
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/9452
dc.language.isoengde
dc.rightsCC-BY-4.0*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleInfluence of cold atmospheric-pressure-plasma in combination with different pretreatment methods on the pull-off tensile load in two-piece abutment-crowns : an in-vitro studyen_GB
dc.typeZeitschriftenaufsatzde
jgu.journal.titleBMC oral healthde
jgu.journal.volume23de
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative186de
jgu.publisher.doi10.1186/s12903-023-02880-9de
jgu.publisher.issn1472-6831de
jgu.publisher.nameBioMed Centralde
jgu.publisher.placeLondonde
jgu.publisher.year2023
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610de
jgu.subject.dfgLebenswissenschaftende
jgu.type.contenttypeScientific articlede
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTextde
jgu.type.versionPublished versionde

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
influence_of_cold_atmospheric-20230818112504767.pdf
Size:
1.22 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.98 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections