Subglottic stenosis imitating the carina : a case report of airway mimicry

dc.contributor.authorTrageser, Heiko
dc.contributor.authorLott, Carsten
dc.contributor.authorEpp, Katharina
dc.contributor.authorPirlich, Nina
dc.date.accessioned2021-06-22T08:35:01Z
dc.date.available2021-06-22T08:35:01Z
dc.date.issued2021
dc.description.abstractWe present a case of awake tracheal intubation with flexible bronchoscopy which resulted in incorrect tracheal tube placement. The presence of a stenotic subglottic lesion with an appearance similar to the carina led to the tube being positioned with only the tip within the trachea whilst the cuff was located between the vocal cords. A capnography trace was identified before induction of anaesthesia; however, visual confirmation of the carina was undertaken in a rushed manner due to the patient becoming agitated. Once the incorrect tracheal tube placement was identified, the decision was made to wake the patient. Thereafter, a more experienced operator successfully performed awake tracheal intubation with flexible bronchoscopy using a smaller tracheal tube, which easily passed through the subglottic stenosis. This report emphasises the importance of performing the ‘two-point check’ every time awake tracheal intubation is undertaken: to confirm correct tube placement, both a capnography trace and view of the tracheal lumen including the carina and main bronchi is required. This must be properly performed before induction of anaesthesia; safety should not be compromised by a stressful environment or time pressure.en_GB
dc.identifier.doihttp://doi.org/10.25358/openscience-6011
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/6020
dc.language.isoeng
dc.rightsCC-BY-NC-ND-4.0
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleSubglottic stenosis imitating the carina : a case report of airway mimicryen_GB
dc.typeZeitschriftenaufsatzde_DE
jgu.apc.pricePAR-Fee
jgu.journal.issue1
jgu.journal.titleAnaesthesia reports
jgu.journal.volume9
jgu.organisation.departmentFB 04 Medizinde_DE
jgu.organisation.nameJohannes Gutenberg-Universität Mainzde_DE
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.end23
jgu.pages.start20
jgu.publisher.doi10.1002/anr3.12094
jgu.publisher.issn2637-3726
jgu.publisher.nameWiley
jgu.publisher.placeHoboken, NJ
jgu.publisher.urihttps://doi.org/10.1002/anr3.12094
jgu.publisher.year2021
jgu.rights.accessrightsopenAccessen_GB
jgu.subject.ddccode610
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTexten_GB
jgu.type.versionPublished versionen_GB

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
trageser_h.-subglottic_ste-20210607144534266.pdf
Size:
98.97 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description: