Compressed sensing acceleration of cardiac cine imaging allows reliable and reproducible assessment of volumetric and functional parameters of the left and right atrium

dc.contributor.authorAltmann, Sebastian
dc.contributor.authorHalfmann, Moritz C.
dc.contributor.authorAbidoye, Ibukun
dc.contributor.authorYacoub, Basel
dc.contributor.authorSchmidt, Michaela
dc.contributor.authorWenzel, Philip
dc.contributor.authorForman, Christoph
dc.contributor.authorSchoepf, U. Joseph
dc.contributor.authorXiong, Fei
dc.contributor.authorDueber, Christoph
dc.contributor.authorKreitner, Karl-Friedrich
dc.contributor.authorVarga-Szemes, Akos
dc.contributor.authorEmrich, Tilman
dc.date.accessioned2022-08-19T07:46:58Z
dc.date.available2022-08-19T07:46:58Z
dc.date.issued2021
dc.description.abstractObjectives To compare volumetric and functional parameters of the atria derived from highly accelerated compressed sensing (CS)–based cine sequences in comparison to conventional (Conv) cine imaging. Methods CS and Conv cine sequences were acquired in 101 subjects (82 healthy volunteers (HV) and 19 patients with heart failure with reduced ejection fraction (HFrEF)) using a 3T MR scanner in this single-center study. Time-volume analysis of the left (LA) and right atria (RA) were performed in both sequences to evaluate atrial volumes and function (total, passive, and active emptying fraction). Inter-sequence and inter- and intra-reader agreement were analyzed using correlation, intraclass correlation (ICC), and Bland-Altman analysis. Results CS-based cine imaging led to a 69% reduction of acquisition time. There was significant difference in atrial parameters between CS and Conv cine, e.g., LA minimal volume (LAVmin) (Conv 24.0 ml (16.7–32.7), CS 25.7 ml (19.2–35.2), p < 0.0001) or passive emptying fraction (PEF) (Conv 53.9% (46.7–58.4), CS 49.0% (42.0–54.1), p < 0.0001). However, there was high correlation between the techniques, yielding good to excellent ICC (0.76–0.99) and small mean of differences in Bland-Altman analysis (e.g. LAVmin − 2.0 ml, PEF 3.3%). Measurements showed high inter- (ICC > 0.958) and intra-rater (ICC > 0.934) agreement for both techniques. CS-based parameters (PEF AUC = 0.965, LAVmin AUC = 0.864) showed equivalent diagnostic ability compared to Conv cine imaging (PEF AUC = 0.989, LAVmin AUC = 0.859) to differentiate between HV and HFrEF. Conclusion Atrial volumetric and functional evaluation using CS cine imaging is feasible with relevant reduction of acquisition time, therefore strengthening the role of CS in clinical CMR for atrial imaging. Key Points • Reliable assessment of atrial volumes and function based on compressed sensing cine imaging is feasible. • Compressed sensing reduces scan time and has the potential to overcome obstacles of conventional cine imaging. • No significant differences for subjective image quality, inter- and intra-rater agreement, and ability to differentiate healthy volunteers and heart failure patients were detected between conventional and compressed sensing cine imaging.en_GB
dc.identifier.doihttp://doi.org/10.25358/openscience-7566
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/7580
dc.language.isoengde
dc.rightsCC-BY-4.0*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleCompressed sensing acceleration of cardiac cine imaging allows reliable and reproducible assessment of volumetric and functional parameters of the left and right atriumen_GB
dc.typeZeitschriftenaufsatzde
jgu.journal.titleEuropean radiologyde
jgu.journal.volume31de
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.end7230de
jgu.pages.start7219de
jgu.publisher.doi10.1007/s00330-021-07830-zde
jgu.publisher.issn1432-1084de
jgu.publisher.nameSpringerde
jgu.publisher.placeBerlin u.a.de
jgu.publisher.year2021
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610de
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTextde
jgu.type.versionPublished versionde

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
compressed_sensing_accelerati-20220815165016768.pdf
Size:
1.81 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description: