Three-dimensional-evaluation of aortic changes after frozen elephant trunk (FET) in zone 0 vs. Zone 2 in acute type A aortic dissection

dc.contributor.authorGhazy, Ahmed
dc.contributor.authorChaban, Ryan
dc.contributor.authorPfeiffer, Philipp
dc.contributor.authorProbst, Chris
dc.contributor.authorDohle, Daniel-Sebastian
dc.contributor.authorTreede, Hendrik
dc.contributor.authorDorweiler, Bernhard
dc.date.accessioned2025-07-30T08:44:03Z
dc.date.available2025-07-30T08:44:03Z
dc.date.issued2024
dc.description.abstractIntroduction: The management of aortic dissection has evolved significantly over the decades, with the frozen elephant trunk (FET) procedure emerging as a key technique for treating complex aortic pathologies. Recent practices involve deploying the FET prosthesis more proximally in the aorta (Zone 0) to reduce complications, leading to questions about its impact on long-term aortic remodeling compared to traditional Zone 2 deployment. Methods: This retrospective analysis utilized 3D segmentation software to assess the volumetric changes in aortic remodeling after acute Type A aortic dissections, comparing FET stent graft deployment in Zone 0 and Zone 2. The study included 27 patients operated on between 2020 and 2022, with volumetric measurements taken from postoperative and 6-month follow-up CT scans. Statistical analyses were performed to evaluate the differences in the aortic true lumen (TL) and the perfused false lumen (PFL) between the two groups. Results: Both Zone 0 and Zone 2 deployments resulted in significant true lumen (TL) increases (Z0 p = 0.001, Z2 p < 0.001) and perfused false lumen (PFL) decreases (Z0 p = 0.02, Z2 p = 0.04), with no significant differences in volumetric changes between the groups (p = 0.7 post op and p = 0.9 after 6 months). The distal anastomosis in Zone 0 did not compromise the aortic remodeling outcomes and was associated with reduced distal ischemia and cerebral perfusion times (p = 0.041). The angle measurements in Zone 0 did not show any significant changes after the 6-month control (p = 0.2). However, in Zone 2, a significant change was detected. (p = 0.022). The part comparison analyses did not indicate significant differences in aortic deviation between the groups (p = 0.62), suggesting comparable effectiveness in aortic remodeling. Conclusions: Performing the distal anastomosis more proximally in Zone 0 offers technical advantages without compromising the effectiveness of aortic remodeling compared to the traditional Zone 2 deployment. This finding supports the continued recommendation of Zone 0 deployment in the management of acute Type A aortic dissections, with ongoing studies being needed to confirm the long-term outcomes and survival benefits.en
dc.identifier.doihttps://doi.org/10.25358/openscience-12947
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/12968
dc.language.isoeng
dc.rightsCC-BY-4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc610 Medizinde
dc.subject.ddc610 Medical sciencesen
dc.titleThree-dimensional-evaluation of aortic changes after frozen elephant trunk (FET) in zone 0 vs. Zone 2 in acute type A aortic dissectionen
dc.typeZeitschriftenaufsatz
jgu.journal.issue9
jgu.journal.titleJournal of Clinical Medicine
jgu.journal.volume13
jgu.organisation.departmentFB 04 Medizin
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative2677
jgu.publisher.doi10.3390/jcm13092677
jgu.publisher.eissn2077-0383
jgu.publisher.nameMDPI
jgu.publisher.placeBasel
jgu.publisher.year2024
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610
jgu.subject.dfgLebenswissenschaften
jgu.type.dinitypeArticleen_GB
jgu.type.resourceText
jgu.type.versionPublished version

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
threedimensionalevaluation_of-20250730104403713474.pdf
Size:
2.35 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
5.1 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections