Do biometric parameters improve the quality of optic nerve head measurements with spectral domain optical coherence tomography?

dc.contributor.authorElksne, Eva
dc.contributor.authorStingl, Julia V.
dc.contributor.authorSchuster, Alexander K.
dc.contributor.authorWagner, Felix M.
dc.contributor.authorHoffmann, Esther M.
dc.date.accessioned2023-02-02T09:19:02Z
dc.date.available2023-02-02T09:19:02Z
dc.date.issued2022
dc.description.abstractBackground Spectral domain optical coherence tomography (SD-OCT) is a widely applied non-invasive technique for evaluating optic nerve head parameters. The aim of this study was to evaluate the impact of biometric parameters such as the spherical equivalent (SE) and the anterior corneal curvature (ACC) on the peripapillary retinal nerve fiber layer (pRNFL), Bruch’s membrane opening (BMO), and the minimum rim width (MRW) measurements performed by spectral domain optical coherence tomography (SD-OCT) in glaucomatous and healthy eyes. Methods In this cross-sectional, case–control prospective pilot study, the glaucoma group consisted of 50 patients with previously diagnosed and treated glaucoma and one healthy group of 50 subjects. Two consecutive examinations of pRNFL, BMO, and MRW with SD-OCT for every patient were performed without ACC and objective refraction (imaging 1) and with them (imaging 2). Results The interclass correlation coefficient (ICC) reflected high agreement between imaging 1 and imaging 2 in both groups. The ICC in the glaucoma and healthy groups for pRNFL (0.99 vs. 0.98), BMO (0.95 vs. 0.97), and MRW (1.0 vs. 1.0) was comparable. Conclusions Our preliminary data from a small number of eyes showed that the measurements of pRNFL, MRW, and BMO reflected high agreement between both imaging techniques with ACC and objective refraction and without these parameters in subjects with a refractive error up to ± 6.0 diopters. Further studies with participants with higher refractive error are necessary to evaluate the impact of biometric parameters such as SE and ACC on measurements with SD-OCT.en_GB
dc.description.sponsorshipGefördert durch die Deutsche Forschungsgemeinschaft (DFG) - Projektnummer 491381577
dc.identifier.doihttp://doi.org/10.25358/openscience-8731
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/8747
dc.language.isoeng
dc.rightsCC-BY-4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleDo biometric parameters improve the quality of optic nerve head measurements with spectral domain optical coherence tomography?en_GB
dc.typeZeitschriftenaufsatzde_DE
jgu.apc.netprice1533,99
jgu.apc.price1825,45
jgu.apc.taxrate19
jgu.apc.transformationcontractSpringer (DEAL)
jgu.dfg.year2022
jgu.journal.titleBMC ophthalmology
jgu.journal.volume22
jgu.nationalcurrency.eur1825,45
jgu.organisation.departmentFB 04 Medizinde_DE
jgu.organisation.nameJohannes Gutenberg-Universität Mainzde_DE
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative56
jgu.publisher.doi10.1186/s12886-022-02281-6
jgu.publisher.issn1471-2415
jgu.publisher.nameBioMed Central
jgu.publisher.placeLondon
jgu.publisher.year2022
jgu.rights.accessrightsopenAccessen_GB
jgu.subject.ddccode610
jgu.subject.dfgLebenswissenschaftende_DE
jgu.type.contenttypeScientific articleen_GB
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTexten_GB
jgu.type.versionPublished versionen_GB

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
do_biometric_parameters_impro-20230131160501481.pdf
Size:
992.37 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections