In 6 day(s), 12 hour(s) and 11 minute(s): Am Montag, den 29.09.2025 steht openscience in der Zeit von 8:30 bis voraussichtlich 10:00 Uhr wegen eines Updates nicht zur Verfügung. Wir bitten die Unannehmlichkeit zu entschuldigen.

Preload and friction in an implant-abutment-screw complex including a carbon-coated titanium alloy abutment screw : an in vitro study

dc.contributor.authorSagheb, Kawe
dc.contributor.authorGörgen, Carolin-Isabel
dc.contributor.authorDöll, Stefan
dc.contributor.authorSchmidtmann, Irene
dc.contributor.authorWentaschek, Stefan
dc.date.accessioned2023-08-24T10:54:15Z
dc.date.available2023-08-24T10:54:15Z
dc.date.issued2023
dc.description.abstractPurpose An experimental approach was designed to measure the preload force, the coefficient of friction and the component of the tightening torque that is needed to surmount the thread-friction in an implant–abutment–screw complex that includes a carbon-coated screw. With the determined preload values the coefficient of friction was calculated. Methods 25 unused complexes, containing an implant, an abutment and a carbon-coated titanium alloy abutment screw, were tested. A custom load frame with two load cells and associated electronics was used. The threads were not lubricated. All abutment screws were torqued ten times to 25 Ncm. The produced preload values and a force that was proportional to the thread-friction component of the tightening torque were recorded. Results Mean preload values decreased significantly with the number of repetitions (p < 0.0001) from initially 329.9 N ± 33.3 (range 255.7 to 383.9) to 253.7 N ± 36.8 (range 200.1 to 332.5) for the last tightening procedure. The corresponding change in the calculated coefficient of friction was 0.33 ± 0.04 (range 0.28 to 0.43) to 0.44 ± 0.07 (range 0.32 to 0.56). For the thread-friction no corresponding trend for consecutive tightening repetitions could be noticed. Conclusions In the investigated implant–abutment units, repeated use of a coated abutment screw appears to increase the friction of the screw head and thereby decrease the preload. These results indicate that a pre-used coated implant–abutment–screw will fail reaching optimal screw preload.en_GB
dc.description.sponsorshipDeutsche Forschungsgemeinschaft (DFG)|491381577|Open-Access-Publikationskosten 2022–2024 Universität Mainz - Universitätsmedizin
dc.identifier.doihttp://doi.org/10.25358/openscience-9436
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/9454
dc.language.isoengde
dc.rightsCC-BY-4.0*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titlePreload and friction in an implant-abutment-screw complex including a carbon-coated titanium alloy abutment screw : an in vitro studyen_GB
dc.typeZeitschriftenaufsatzde
jgu.journal.titleInternational journal of implant dentistryde
jgu.journal.volume9de
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative8de
jgu.publisher.doi10.1186/s40729-023-00473-3de
jgu.publisher.issn2198-4034de
jgu.publisher.nameSpringerde
jgu.publisher.placeBerlin u.a.de
jgu.publisher.urihttps://doi.org/10.1186/s40729-023-00473-3de
jgu.publisher.year2023
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610de
jgu.subject.dfgLebenswissenschaftende
jgu.type.contenttypeScientific articlede
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTextde
jgu.type.versionPublished versionde

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
preload_and_friction_in_an_im-20230818113652040.pdf
Size:
1.8 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.98 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections