Multicentre comparison of various microaxial pump devices as a bridge to durable assist device implantation

dc.contributor.authorMedina, Marta L.
dc.contributor.authorLewin, Daniel
dc.contributor.authorTreede, Hendrik
dc.contributor.authorRojas, Sebastian V.
dc.contributor.authorBernhardt, Alexander
dc.contributor.authorBillion, Michael
dc.contributor.authorMeyer, Anna L.
dc.contributor.authorNetuka, Ivan
dc.contributor.authorKooij, Janajade
dc.contributor.authorPieri, Marina
dc.contributor.authorLoforte, Antonio
dc.contributor.authorRinaldi, Mauro
dc.contributor.authorSzymanski, Mariusz K.
dc.contributor.authorKraajieveld, Adriaan O.
dc.contributor.authorMoeller, Christian J.H.
dc.contributor.authorAkhyari, Payam
dc.contributor.authorJawad, Khalil
dc.contributor.authorSchmack, Bastian
dc.contributor.authorFärber, Gloria
dc.contributor.authorHaneya, Assad
dc.contributor.authorZimpfer, Daniel
dc.contributor.authorNersesian, Gaik
dc.contributor.authorDjordjevic, Ilija
dc.contributor.authorSaeed, Diyar
dc.contributor.authorGustafsson, Finn
dc.contributor.authorScandroglio, Anna M.
dc.contributor.authorMeyns, Bart
dc.contributor.authorHofmann, Steffen
dc.contributor.authorBelohlavek, Jan
dc.contributor.authorGummert, Jan
dc.contributor.authorLanmueller, Pia
dc.contributor.authorPotapov, Evgenij V.
dc.contributor.authorOezkur, Mehmet
dc.date.accessioned2025-09-30T09:32:09Z
dc.date.issued2025
dc.description.abstractAims: Patients with acute decompensated advanced heart failure requiring left ventricular assist device (LVAD) implantation often experience progressive cardiac function deterioration, negatively impacting surgical outcomes. This study aimed to assess the efficacy of different microaxial flow pump (mAFP) support devices (Impella®) in achieving optimal left ventricular unloading for preconditioning and facilitating definitive treatment in this high-risk patient cohort. Methods and results: A retrospective analysis was conducted across 19 high-volume European centres. The study population included patients transitioning from temporary to durable circulatory support over a 7.5-year period, with a median follow-up of 1 year. Patients were categorized based on mAFP support capacity: those receiving high-flow support (>5 L/min, ‘5+’) and those with lower-flow support (3.5 L/min, ‘CP’). Patients who were initially treated with CP but subsequently upgraded to 5+ support were classified in the 5+ group. Demographic and clinical characteristics, mobilization, right heart function, and organ dysfunction outcomes were analysed. A total of 339 patients received preoperative mAFP support prior to LVAD implantation. The 5+ group comprised 247 patients (73%), including 38 patients who were upgraded from CP, while the CP group included 92 patients (27%). Baseline demographic and clinical characteristics were comparable between groups, except for mobilization status, which showed significant differences (P < 0.001). Patients in the 5+ group achieved higher rates of full and partial mobilization compared to the CP group. Extracorporeal life support (ECLS) was more frequently required in the CP group than in the 5+ group (40.5% vs. 33.8%; P < 0.001). Additionally, right ventricular assist device (RVAD) implantation was significantly more common in the CP group (29.2% vs. 18.2%; P = 0.026). Patients in the 5+ group demonstrated greater reductions in both vasoactive inotropic scores (P = 0.006) and inotropic scores (P = 0.008). Furthermore, liver dysfunction (P = 0.016), renal failure (P = 0.041), and the need for dialysis (P = 0.013) were significantly more prevalent in the CP group. There were no significant differences between the two groups in terms of LVAD operative duration (P = 0.637) or cardiopulmonary bypass time (P = 0.408). Conclusions: High-flow mAFP devices (+5) provided superior haemodynamic support, enhanced left ventricular unloading, and reduced dependence on catecholamines compared to lower-flow CP devices. These improvements were associated with lower rates of right ventricular failure, renal dysfunction, and liver injury. However, no statistically significant difference was observed between mAFP groups regarding 30-day mortality rates.en
dc.identifier.doihttps://doi.org/10.25358/openscience-13406
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/13427
dc.language.isoeng
dc.rightsCC-BY-4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc610 Medizinde
dc.subject.ddc610 Medical sciencesen
dc.titleMulticentre comparison of various microaxial pump devices as a bridge to durable assist device implantationen
dc.typeZeitschriftenaufsatz
jgu.identifier.uuid4b22ab6d-0ea6-4d83-aef6-b0b9f1f1d9d1
jgu.journal.issue4
jgu.journal.titleESC heart failure
jgu.journal.volume12
jgu.organisation.departmentFB 04 Medizin
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.end2564
jgu.pages.start2552
jgu.publisher.doi10.1002/ehf2.15282
jgu.publisher.eissn2055-5822
jgu.publisher.nameWiley
jgu.publisher.placeChichester
jgu.publisher.year2025
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610
jgu.subject.dfgLebenswissenschaften
jgu.type.dinitypeArticleen_GB
jgu.type.resourceText
jgu.type.versionPublished version

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
multicentre_comparison_of_var-20250930113209632113.pdf
Size:
898.72 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
5.14 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections