Transjugular portosystemic stent shunt : impact of right atrial pressure on portal venous hemodynamics within the first week

dc.contributor.authorPitton, Michael Bernhard
dc.contributor.authorWeinmann, Arndt
dc.contributor.authorKloeckner, Roman
dc.contributor.authorMittler, Jens
dc.contributor.authorRuckes, Christian
dc.contributor.authorDüber, Christoph
dc.contributor.authorOtto, Gerd
dc.date.accessioned2022-08-24T09:34:08Z
dc.date.available2022-08-24T09:34:08Z
dc.date.issued2022
dc.description.abstractPurpose Porto-systemic pressure gradient is used to prognosticate rebleeding and resolution of ascites after TIPS. This study investigates the reliability of portal pressure characteristics as quantified immediately after TIPS placement and at short-term control. Patients and Methods Portal venous pressure (PVP) and right atrial pressure (RAP) were prospectively obtained before and after TIPS as well as ≥ 48 h after TIPS procedure. Porto-systemic pressure gradients (PSG) and pressure changes were calculated. A multivariate regression analysis was performed to predict portal hemodynamics at short-term control. Results The study included 124 consecutive patients. Indications for TIPS were refractory ascites, variceal bleeding or combinations of both. Pre- and post-interventional PSG yielded 16.4 ± 5.3 mmHg and 5.9 ± 2.7 mmHg, respectively. At that time, 105/124 patients (84.7%) met the target (PSG ≤ 8 mmHg). After 4 days (median), PSG was 8.5 ± 3.5 mmHg and only 66 patients (53%) met that target. In patients exceeding the target PSG at follow-up, PVP was significantly higher and RAP was lower resulting in the increased PSG. The highly variable changes of RAP were the main contributor to different pressure gradients. In the multivariate regression analysis, PVP and RAP immediately after TIPS were predictors for PSG at short-term control with moderately predictive capacity (AUC = 0.75). Conclusion Besides the reduction of portal vein pressure, the highly variable right atrial pressure was the main contributor to different pressure gradients. Thus, immediate post-TIPS measurements do not reliably predict portal hemodynamics during follow-up. These findings need to be further investigated with respect to the corresponding clinical course of the patients.en_GB
dc.identifier.doihttp://doi.org/10.25358/openscience-7612
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/7626
dc.language.isoengde
dc.rightsCC-BY-4.0*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleTransjugular portosystemic stent shunt : impact of right atrial pressure on portal venous hemodynamics within the first weeken_GB
dc.typeZeitschriftenaufsatzde
jgu.journal.titleCardioVascular and interventional radiologyde
jgu.journal.volume45de
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.end111de
jgu.pages.start102de
jgu.publisher.doi10.1007/s00270-021-03003-zde
jgu.publisher.issn1432-086Xde
jgu.publisher.nameSpringerde
jgu.publisher.placeBerlin u.a.de
jgu.publisher.year2022
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610de
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTextde
jgu.type.versionPublished versionde

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
transjugular_portosystemic_st-20220822160202310.pdf
Size:
523.79 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description: