Intraindividual reproducibility of myocardial radiomic features between energy-integrating detector and photon-counting detector CT angiography

dc.contributor.authorTremamunno, Giuseppe
dc.contributor.authorVarga-Szemes, Akos
dc.contributor.authorSchoepf, U. Joseph
dc.contributor.authorLaghi, Andrea
dc.contributor.authorZsarnoczay, Emese
dc.contributor.authorFink, Nicola
dc.contributor.authorAquino, Gilberto J.
dc.contributor.authorO’Doherty, Jim
dc.contributor.authorEmrich, Tilman
dc.contributor.authorVecsey-Nagy, Milan
dc.date.accessioned2024-12-12T14:17:37Z
dc.date.available2024-12-12T14:17:37Z
dc.date.issued2024
dc.description.abstractBackground: Radiomics is not yet used in clinical practice due to concerns regarding its susceptibility to technical factors. We aimed to assess the stability and interscan and interreader reproducibility of myocardial radiomic features between energy-integrating detector computed tomography (EID-CT) and photon-counting detector CT (PCD-CT) in patients undergoing coronary CT angiography (CCTA) on both systems. Methods: Consecutive patients undergoing clinically indicated CCTA on an EID-CT were prospectively enrolled for a PCD-CT CCTA within 30 days. Virtual monoenergetic images (VMI) at various keV levels and polychromatic images (T3D) were generated for PCD-CT, with image reconstruction parameters standardized between scans. Two readers performed myocardial segmentation and 110 radiomic features were compared intraindividually between EID-CT and PDC-CT series. The agreement of parameters was assessed using the intraclass correlation coefficient and paired t-test for the stability of the parameters. Results:en_GB
dc.identifier.doihttp://doi.org/10.25358/openscience-11117
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/11136
dc.language.isoengde
dc.rightsCC-BY-4.0*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleIntraindividual reproducibility of myocardial radiomic features between energy-integrating detector and photon-counting detector CT angiographyen_GB
dc.typeZeitschriftenaufsatzde
jgu.journal.titleEuropean radiology experimentalde
jgu.journal.volume8de
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative101de
jgu.publisher.doi10.1186/s41747-024-00493-7de
jgu.publisher.issn2509-9280de
jgu.publisher.nameSpringerde
jgu.publisher.placeChamde
jgu.publisher.year2024
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610de
jgu.subject.dfgLebenswissenschaftende
jgu.type.contenttypeScientific articlede
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTextde
jgu.type.versionPublished versionde

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
intraindividual_reproducibili-20241212151634380.pdf
Size:
1.9 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections