Effects of internal cooling on physical performance, physiological and perceptional parameters when exercising in the heat: A systematic review with meta-analyses

dc.contributor.authorHeydenreich, Juliane
dc.contributor.authorKoehler, Karsten
dc.contributor.authorGrosshauser, Mareike
dc.contributor.authorHeseker, Helmut
dc.contributor.authorKoenig, Daniel
dc.contributor.authorLampen, Alfonso
dc.contributor.authorMosler, Stephanie
dc.contributor.authorNiess, Andreas
dc.contributor.authorSchenk, Alexandra
dc.contributor.authorCarlsohn, Anja
dc.date.accessioned2023-07-26T06:05:31Z
dc.date.available2023-07-26T06:05:31Z
dc.date.issued2023
dc.description.abstractBackground: An elevated core temperature (Tcore) increases the risk of performance impairments and heat-related illness. Internal cooling (IC) has the potential to lower Tcore when exercising in the heat. The aim of the review was to systematically analyze the effects of IC on performance, physiological, and perceptional parameters. Methods: A systematic literature search was performed in the PubMed database on 17 December 2021. Intervention studies were included assessing the effects of IC on performance, physiological, or perceptional outcomes. Data extraction and quality assessment were conducted for the included literature. The standardized mean differences (SMD) and 95% Confidence Intervals (CI) were calculated using the inverse-variance method and a random-effects model. Results: 47 intervention studies involving 486 active subjects (13.7% female; mean age 20–42 years) were included in the meta-analysis. IC resulted in significant positive effects on time to exhaustion [SMD (95% CI) 0.40 (0.13; 0.67), p < 0.01]. IC significantly reduced Tcore [−0.19 (22120.34; −0.05), p < 0.05], sweat rate [−0.20 (−0.34; −0.06), p < 0.01], thermal sensation [−0.17 (−0.33; −0.01), p < 0.05], whereas no effects were found on skin temperature, blood lactate, and thermal comfort (p > 0.05). IC resulted in a borderline significant reduction in time trial performance [0.31 (−0.60; −0.02), p = 0.06], heart rate [−0.13 (−0.27; 0.01), p = 0.06], rate of perceived exertion [−0.16 (−0.31; −0.00), p = 0.05] and borderline increased mean power output [0.22 (0.00; 0.44), p = 0.05]. Discussion: IC has the potential to affect endurance performance and selected physiological and perceptional parameters positively. However, its effectiveness depends on the method used and the time point of administration. Future research should confirm the laboratory-based results in the field setting and involve non-endurance activities and female athletes.en_GB
dc.identifier.doihttp://doi.org/10.25358/openscience-9316
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/9334
dc.language.isoengde
dc.rightsCC-BY-4.0*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc333.7 Natürliche Ressourcende_DE
dc.subject.ddc333.7 Natural resourcesen_GB
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.subject.ddc796 Sportde_DE
dc.subject.ddc796 Athletic and outdoor sports and gamesen_GB
dc.subject.ddc910 Geografiede_DE
dc.subject.ddc910 Geography and travelen_GB
dc.titleEffects of internal cooling on physical performance, physiological and perceptional parameters when exercising in the heat: A systematic review with meta-analysesen_GB
dc.typeZeitschriftenaufsatzde
jgu.journal.titleFrontiers in Physiologyde
jgu.journal.volume14de
jgu.organisation.departmentFB 02 Sozialwiss., Medien u. Sportde
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number7910
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative1125969de
jgu.publisher.doi10.3389/fphys.2023.1125969de
jgu.publisher.issn1664-042Xde
jgu.publisher.nameFrontiersde
jgu.publisher.placeLausannede
jgu.publisher.year2023
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode333.7de
jgu.subject.ddccode610de
jgu.subject.ddccode796de
jgu.subject.ddccode910de
jgu.subject.dfgGeistes- und Sozialwissenschaftende
jgu.type.contenttypeScientific articlede
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTextde
jgu.type.versionPublished versionde

Files

Original bundle

Now showing 1 - 5 of 7
Loading...
Thumbnail Image
Name:
effects_of_internal_cooling_o-20230725115158725.pdf
Size:
5.76 MB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
effects_of_internal_cooling_o-20230725115211539.pdf
Size:
585.89 KB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
effects_of_internal_cooling_o-20230725115211834.pdf
Size:
771.86 KB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
effects_of_internal_cooling_o-20230725115212172.pdf
Size:
400.74 KB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
effects_of_internal_cooling_o-20230725115212443.PDF
Size:
582.63 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.98 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections