A highly segmented neutron polarimeter for A1

dc.contributor.authorSpreckels, Rouven
dc.contributor.authorHoek, Matthias
dc.contributor.authorMüller, Ulrich
dc.contributor.authorAchenbach, Patrick
dc.contributor.authorBosnar, Damir
dc.contributor.authorCaiazza, Stefano S.
dc.contributor.authorDistler, Michael O.
dc.contributor.authorDoria, Luca
dc.contributor.authorEckert, P.
dc.contributor.authorEsser, Anselm
dc.contributor.authorFonvieille, Helene
dc.contributor.authorGeimer, Jennifer L. Burnfield
dc.contributor.authorHerrmann, P.
dc.contributor.authorKegel, Simon
dc.contributor.authorKlag, Pascal
dc.contributor.authorLunkenheimer, S.
dc.contributor.authorMakek, Mihael
dc.contributor.authorMarkus, David
dc.contributor.authorMerkel, Harald
dc.contributor.authorMihovilovič, Miha
dc.contributor.authorMüller, J.
dc.contributor.authorPochodzalla, Josef
dc.contributor.authorRausch, J.
dc.contributor.authorSchlimme, Björn Sören
dc.contributor.authorSfienti, Concettina
dc.contributor.authorŠirca, Simon
dc.date.accessioned2025-07-25T09:27:15Z
dc.date.available2025-07-25T09:27:15Z
dc.date.issued2024
dc.description.abstractA new neutron polarimeter for measuring the neutron’s electric form factor was designed and constructed to complement the A1 spectrometer setup at the Mainz Microtron (MAMI). The design is based on a previous polarimeter with significant improvements to halve the error of the extracted form factor. A higher granularity of the polarimeter sections and a deeper first section on the one hand, and a faster readout employing Time-over-Threshold methods to measure the signal amplitudes combined with a high-precision FPGA-based TDC on the other hand will allow to achieve this goal. The performance of the new polarimeter during a first measurement campaign in 2019 using liquid hydrogen and deuterium targets will be discussed.en_GB
dc.identifier.doihttps://doi.org/10.25358/openscience-12850
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/12871
dc.language.isoeng
dc.rightsCC-BY-4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc530 Physikde_DE
dc.subject.ddc530 Physicsen_GB
dc.titleA highly segmented neutron polarimeter for A1en_GB
dc.typeZeitschriftenaufsatzde_DE
jgu.apc.netprice2255,71
jgu.apc.price2413,62
jgu.apc.taxrate7
jgu.apc.transformationcontractElsevier
jgu.dfg.year2024
jgu.journal.titleNuclear instruments & methods in physics research : A
jgu.journal.volume1062
jgu.nationalcurrency.eur2255,71
jgu.organisation.departmentFB 08 Physik, Mathematik u. Informatikde_DE
jgu.organisation.nameJohannes Gutenberg-Universität Mainzde_DE
jgu.organisation.number7940
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative169171
jgu.publisher.doi10.1016/j.nima.2024.169171
jgu.publisher.eissn1872-9576
jgu.publisher.nameElsevier
jgu.publisher.placeAmsterdam
jgu.publisher.year2024
jgu.rights.accessrightsopenAccessen_GB
jgu.subject.ddccode530
jgu.subject.dfgNaturwissenschaftende_DE
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTexten_GB
jgu.type.versionPublished versionen_GB

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
a_highly_segmented_neutron_po-20250725112715855768.pdf
Size:
2.51 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
5.1 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections