Evaluation of gender differences in postoperative sore throat and hoarseness following the use of Ambu AuraGain laryngeal mask : the randomised controlled LadyLAMA trial study protocol

dc.contributor.authorEpp, Katharina
dc.contributor.authorPrzybylski, Uli
dc.contributor.authorLuz, Carla
dc.contributor.authorKriege, Marc
dc.contributor.authorWittenmeier, Eva
dc.contributor.authorSchmidtmann, Irene
dc.contributor.authorPirlich, Nina
dc.date.accessioned2023-01-26T08:27:58Z
dc.date.available2023-01-26T08:27:58Z
dc.date.issued2022
dc.description.abstractIntroduction Postoperative sore throat (POST) is a comparatively minor but very common side effect of general anaesthesia with a supraglottic airway device. The patient considers these side effects a mirror of the quality of anaesthesia. The aims of this study are to evaluate gender-specific differences in the incidence of POST and to assess whether the effects of known risk factors vary between genders. Methods and analysis The LadyLAMA trial is a single-centre, patient-blinded, randomised controlled trial. Consecutive patients requiring ophthalmological surgery under general anaesthesia with a second generation Ambu AuraGain laryngeal mask are randomly allocated to either cuff pressure of 45 cmH2O or cuff pressure of 60 cmH2O. We estimate the difference in POST between the genders at 20% and we hypothesised that a reduction of cuff pressure would reduce POST by 10%. A total of 800 patients will be recruited, with each subgroup including 200 patients to achieve 80% power for detecting a difference at the 5% significance level. Primary endpoints are gender differences in the incidence of POST within 24 hours postoperatively, as well as comparison of cuff pressure 45 cmH2O to 60 cmH2O with respect to POST. The main secondary objective is the effect of cuff pressure on POST stratified by gender. Further secondary endpoints are gender-specific differences in POST and hoarseness in postanaesthesia care unit (PACU) at 48 and 72 hours (or until freedom of discomfort). The parameter cuff pressure serves as key-secondary endpoint.en_GB
dc.description.sponsorshipGefördert durch die Deutsche Forschungsgemeinschaft (DFG) - Projektnummer 491381577de
dc.identifier.doihttp://doi.org/10.25358/openscience-8646
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/8662
dc.language.isoengde
dc.rightsCC-BY-NC-4.0*
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleEvaluation of gender differences in postoperative sore throat and hoarseness following the use of Ambu AuraGain laryngeal mask : the randomised controlled LadyLAMA trial study protocolen_GB
dc.typeZeitschriftenaufsatzde
jgu.journal.issue1de
jgu.journal.titleBMJ Opende
jgu.journal.volume12de
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternativee056465de
jgu.publisher.doi10.1136/bmjopen-2021-056465de
jgu.publisher.issn2044-6055de
jgu.publisher.nameBMJ Publishing Groupde
jgu.publisher.placeLondonde
jgu.publisher.year2022
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610de
jgu.subject.dfgLebenswissenschaftende
jgu.type.contenttypeScientific articlede
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTextde
jgu.type.versionPublished versionde

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
valuation_of_gender_differenc-20230124124828714.pdf
Size:
966.77 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections