The accuracy of robotic-assisted zygomatic implant placement : a systematic review and meta-analysis

dc.contributor.authorFan, Shengchi
dc.contributor.authorSingkhorn, Thidarat
dc.contributor.authorSáenz-Ravello, Gustavo
dc.contributor.authorMattheos, Nikos
dc.contributor.authorDavó, Rubén
dc.contributor.authorChow, James
dc.contributor.authorAl-Nawas, Bilal
dc.date.accessioned2026-08-31T06:47:35Z
dc.date.issued2026
dc.description.abstractBackground This is the first systematic review and meta-analysis aimed at assessing the current status of robotic-assisted implant surgery (r-CAIS) in zygomatic implant (ZI) placement, with a particular focus on deviations between planned and placed implant positions. Materials and methods The review protocol was specified and registered in PROSPERO (CRD42024616949). All primary studies were considered eligible, including in vitro studies, clinical studies, and hybrid experimental–clinical studies. Electronic and manual literature searches were conducted through April 2025 in PubMed/MEDLINE, Scopus, the Cochrane Library, and Web of Science. The primary outcome was planned/placed deviation with or without other implant placement techniques. Results Ten studies (seven in vitro, two clinical, and one hybrid experimental–clinical) involving 185 ZIs in 83 models /patients were included. Of these, nine studies were eligible for quantitative synthesis, contributing 161 ZIs placed using r-CAIS and 97 using dynamic CAIS (d-CAIS) to the pooled mean meta-analysis. The pooled mean ZI deviations from the r-CAIS group were 1.04 mm (95% CI: 0.74–1.35 mm) at the entry point and 1.47 mm (95% CI: 1.07–1.87 mm) at the exit point, and angular deviations were 1.22° (95% CI: 0.82–1.62°). The pooled mean ZI deviations from the d-CAIS group were 1.30 mm (95% CI: 1.00–1.60 mm) at the entry point and 2.02 mm (95% CI: 1.81–2.23 mm) at the exit point, and angular deviations were 2.00° (95% CI: 1.33–2.67°). Significant differences in deviation were observed at the exit and angular levels in favor of r-CAIS. Conclusions r-CAIS demonstrates significantly superior accuracy compared with d-CAIS in ZIs placement. However, as r-CAIS remains at an early stage of clinical integration and only limited clinical studies have been reported, its long-term applicability requires further validation through cadaveric and well-designed prospective clinical investigations.en_GB
dc.identifier.doihttps://doi.org/10.25358/openscience-16169
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/16190
dc.language.isoeng
dc.rightsCC-BY-4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_EN
dc.titleThe accuracy of robotic-assisted zygomatic implant placement : a systematic review and meta-analysisen_GB
dc.typeZeitschriftenaufsatzde_DE
jgu.apc.netprice1838,95
jgu.apc.price1967,68
jgu.apc.taxrate7
jgu.apc.transformationcontractSpringer (DEAL)
jgu.dfg.year2026
jgu.identifier.uuid0943955f-142c-453e-97b4-920e27b38233
jgu.journal.titleBMC oral health
jgu.journal.volume26
jgu.nationalcurrency.eur1838,95
jgu.organisation.departmentFB 04 Medizinde_DE
jgu.organisation.nameJohannes Gutenberg-Universität Mainzde_DE
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternative778
jgu.publisher.doi10.1186/s12903-026-07816-7
jgu.publisher.eissn1472-6831
jgu.publisher.nameBioMed Central
jgu.publisher.placeLondon
jgu.publisher.year2026
jgu.relation.IsVersionOf10.1186/s12903-026-07816-7
jgu.rights.accessrightsopenAccessen_GB
jgu.subject.ddccode610
jgu.subject.dfgLebenswissenschaftende_DE
jgu.type.contenttypeReviewen_GB
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTexten_GB
jgu.type.versionPublished versionen_GB

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
the_accuracy_of_roboticassist-20260831064735801264.pdf
Size:
3.02 MB
Format:
Adobe Portable Document Format

Collections