Autoren: Birklein, Lukas
Niebler, Stefan
Schömer, Elmar
Brylka, Robert
Schwanecke, Ulrich
Schulze, Ralf
Titel: Motion correction for separate mandibular and cranial movements in cone beam CT reconstructions
Online-Publikationsdatum: 3-Aug-2023
Erscheinungsdatum: 2023
Sprache des Dokuments: Englisch
Zusammenfassung/Abstract: Background Patient motions are a repeatedly reported phenomenon in oral and maxillofacial cone beam CT scans, leading to reconstructions of limited usability. In certain cases, independent movements of the mandible induce unpredictable motion patterns. Previous motion correction methods are not able to handle such complex cases of patient movements. Purpose Our goal was to design a combined motion estimation and motion correction approach for separate cranial and mandibular motions, solely based on the 2D projection images from a single scan. Methods Our iterative three-step motion correction algorithm models the two articulated motions as independent rigid motions. First of all, we segment cranium and mandible in the projection images using a deep neural network. Next, we compute a 3D reconstruction with the poses of the object's trajectories fixed. Third, we improve all poses by minimizing the projection error while keeping the reconstruction fixed. Step two and three are repeated alternately. Results We find that our marker-free approach delivers reconstructions of up to 85% higher quality, with respect to the projection error, and can improve on already existing techniques, which model only a single rigid motion. We show results of both synthetic and real data created in different scenarios. The reconstruction of motion parameters in a real environment was evaluated on acquisitions of a skull mounted on a hexapod, creating a realistic, easily reproducible motion profile. Conclusions The proposed algorithm consistently enhances the visual quality of motion impaired cone beam computed tomography scans, thus eliminating the need for a re-scan in certain cases, considerably lowering radiation dosage for the patient. It can flexibly be used with differently sized regions of interest and is even applicable to local tomography.
DDC-Sachgruppe: 004 Informatik
004 Data processing
Veröffentlichende Institution: Johannes Gutenberg-Universität Mainz
Organisationseinheit: FB 08 Physik, Mathematik u. Informatik
Veröffentlichungsort: Mainz
ROR: https://ror.org/023b0x485
DOI: http://doi.org/10.25358/openscience-9342
Version: Published version
Publikationstyp: Zeitschriftenaufsatz
Nutzungsrechte: CC BY
Informationen zu den Nutzungsrechten: https://creativecommons.org/licenses/by/4.0/
Zeitschrift: Medical physics
50
6
Seitenzahl oder Artikelnummer: 3511
3525
Verlag: Wiley
Verlagsort: Hoboken, NJ
Erscheinungsdatum: 2023
ISSN: 0094-2405
DOI der Originalveröffentlichung: 10.1002/mp.16347
Enthalten in den Sammlungen:DFG-491381577-H

Dateien zu dieser Ressource:
  Datei Beschreibung GrößeFormat
Miniaturbild
motion_correction_for_separat-20230724140945582.pdfPublished version3.19 MBAdobe PDFÖffnen/Anzeigen