Autoren: | Graafen, Dirk |
Titel: | Dosis und Bildqualität der Photon-Counting HRCT der Lunge |
Online-Publikationsdatum: | 10-Mär-2023 |
Erscheinungsdatum: | 2023 |
Sprache des Dokuments: | Englisch |
Zusammenfassung/Abstract: | Purpose: Photon-counting detector computed tomography (PCD-CT) has the potential to significantly improve CT imaging in many ways including, but not limited to, low-dose high-resolution CT (HRCT) of the lung. The aim of this study was to perform an intrapatient com- parison of the radiation dose and image quality of PCD-CT compared with conventional energy-integrating detector CT (EID-CT). Methods: A total of 32 consecutive patients with available PCD-CT and EID-CT HRCT scans were included in the final analysis. The CT dose index (CTDIvol) was extracted from patient dose reports. Qualitative image analysis comprised the lung parenchyma and mediastinal struc- tures and was assessed by 3 readers using a 5-point Likert scale. Quan- titative image analysis included assessment of noise and signal-to-noise ratio in the lung parenchyma, trachea, aorta, muscle, and background. Results: The mean CTDIvol was 2.0 times higher in the conventional EID-CT scans (1.8 ± 0.5 mGy) compared with PCD-CT (0.9±0.5 mGy, P<0.001). The overall image quality was rated significantly better by all 3 raters (P < 0.001) in the PCD-CT relative to the EID-CT. Quantitative analysis showed no significant differ- ences in noise and signal-to-noise ratio in the lung parenchyma between PCD-CT and EID-CT. Conclusion: Compared with conventional EID-CT scans, PCD-CT demonstrated similar or better objective and subjective image quality at significantly reduced dose levels in an intrapatient com- parison. These results and their effect on clinical decision-making should be further investigated in prospective studies. |
DDC-Sachgruppe: | 610 Medizin 610 Medical sciences |
Veröffentlichende Institution: | Johannes Gutenberg-Universität Mainz |
Organisationseinheit: | FB 04 Medizin |
Veröffentlichungsort: | Mainz |
ROR: | https://ror.org/023b0x485 |
DOI: | http://doi.org/10.25358/openscience-8880 |
URN: | urn:nbn:de:hebis:77-openscience-ce64bdb1-3893-4609-b9d7-e2c501ec70eb0 |
Version: | Original work |
Publikationstyp: | Dissertation |
Nutzungsrechte: | Urheberrechtsschutz |
Informationen zu den Nutzungsrechten: | http://rightsstatements.org/vocab/InC/1.0/ |
Umfang: | 16 Blatt ; Illustrationen, Diagramme |
Enthalten in den Sammlungen: | JGU-Publikationen |
Dateien zu dieser Ressource:
Datei | Beschreibung | Größe | Format | ||
---|---|---|---|---|---|
![]() | dosis_und_bildqualität_der_ph-20230305143736063.pdf | 2.18 MB | Adobe PDF | Öffnen/Anzeigen |