Dosis und Bildqualität der Photon-Counting HRCT der Lunge

dc.contributor.authorGraafen, Dirk
dc.date.accessioned2023-03-10T07:53:47Z
dc.date.available2023-03-10T07:53:47Z
dc.date.issued2023
dc.description.abstractPurpose: Photon-counting detector computed tomography (PCD-CT) has the potential to significantly improve CT imaging in many ways including, but not limited to, low-dose high-resolution CT (HRCT) of the lung. The aim of this study was to perform an intrapatient com- parison of the radiation dose and image quality of PCD-CT compared with conventional energy-integrating detector CT (EID-CT). Methods: A total of 32 consecutive patients with available PCD-CT and EID-CT HRCT scans were included in the final analysis. The CT dose index (CTDIvol) was extracted from patient dose reports. Qualitative image analysis comprised the lung parenchyma and mediastinal struc- tures and was assessed by 3 readers using a 5-point Likert scale. Quan- titative image analysis included assessment of noise and signal-to-noise ratio in the lung parenchyma, trachea, aorta, muscle, and background. Results: The mean CTDIvol was 2.0 times higher in the conventional EID-CT scans (1.8 ± 0.5 mGy) compared with PCD-CT (0.9±0.5 mGy, P<0.001). The overall image quality was rated significantly better by all 3 raters (P < 0.001) in the PCD-CT relative to the EID-CT. Quantitative analysis showed no significant differ- ences in noise and signal-to-noise ratio in the lung parenchyma between PCD-CT and EID-CT. Conclusion: Compared with conventional EID-CT scans, PCD-CT demonstrated similar or better objective and subjective image quality at significantly reduced dose levels in an intrapatient com- parison. These results and their effect on clinical decision-making should be further investigated in prospective studies.en_GB
dc.identifier.doihttp://doi.org/10.25358/openscience-8880
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/8896
dc.identifier.urnurn:nbn:de:hebis:77-openscience-ce64bdb1-3893-4609-b9d7-e2c501ec70eb0
dc.language.isoengde
dc.rightsInC-1.0*
dc.rights.urihttps://rightsstatements.org/vocab/InC/1.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleDosis und Bildqualität der Photon-Counting HRCT der Lungede_DE
dc.typeDissertationde
jgu.date.accepted2023-02-27
jgu.description.extent16 Blatt ; Illustrationen, Diagrammede
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.organisation.year2022
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610de
jgu.type.dinitypePhDThesisen_GB
jgu.type.resourceTextde
jgu.type.versionOriginal workde

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
dosis_und_bildqualität_der_ph-20230305143736063.pdf
Size:
2.13 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description: