Autoren: | Kriege, Marc Rissel, René Heid, Florian Ott, Thomas El Beyrouti, Hazem Hotz, Eric |
Titel: | Airway management with novel intubating laryngeal tubes has no influence on cerebral oxygenation in cardiac surgery patients: a prospective observational study |
Online-Publikationsdatum: | 24-Jan-2023 |
Erscheinungsdatum: | 2022 |
Sprache des Dokuments: | Englisch |
Zusammenfassung/Abstract: | Background: A laryngeal tube is often used as an alternative to intubation with direct laryngoscopy during cardiopulmonary resuscitation. However, in a study with piglets undergoing simulated cardiac arrest, reduced carotid artery blood flow was associated with the insertion of different supraglottic airway devices, such as a laryngeal tube. Limited by its construction, secondary tracheal intubation through a laryngeal tube was difficult or impossible in contrast to a second generation laryngeal mask. The new disposable intubating laryngeal tube with suction (iLTS-D®) seems to facilitate tracheal intubation. We hypothesized that iLTS-D, when inflated to the recommended air volume, does not reduce cerebral oxygenation in patients with cardiovascular diseases undergoing elective cardiac surgery. Methods: This single-center prospective, controlled observational study was approved by the local ethics committee (Ethical Committee No. 2018-13716). Forty adult patients undergoing elective cardiac surgery requiring tracheal intubation were included in this study. The exclusion criteria were age <18 years and a high risk of aspiration, inability to consent, height <155 cm, or pregnancy. Prior to insufflation and deflation of the cuffs, we performed cerebral oximetry via near-infrared spectroscopy. The primary outcome was a significant reduction in NIRS in the context of the preinduction baseline value after inflation of the cuffs with the recommended air volume, defined as a ≥25% decrease from baseline or an absolute value ≤ 50%. The secondary endpoints were differences in time points, insertion success rates, and complications. Results: There was no significant reduction in cerebral oximetry after inflation with the recommended cuff volume and an initially measured cuff pressure of >120 cmH2O. Overall, tracheal intubation was achieved in a median of 20 s [interquartile range 15-23 s] and enabled sufficient ventilation and tracheal intubation through the iLTS-D in all patients. Traces of blood on the cuffs (after removing the iLTS-D) and a sore throat (evaluated 2 h after removing the tracheal tube) were observed in one patient. Conclusion: Our results showed no association between the insertion of the iLTS-D and reduced cerebral oxygenation in patients undergoing elective cardiac surgery. |
DDC-Sachgruppe: | 610 Medizin 610 Medical sciences |
Veröffentlichende Institution: | Johannes Gutenberg-Universität Mainz |
Organisationseinheit: | FB 04 Medizin |
Veröffentlichungsort: | Mainz |
ROR: | https://ror.org/023b0x485 |
DOI: | http://doi.org/10.25358/openscience-8615 |
Version: | Published version |
Publikationstyp: | Zeitschriftenaufsatz |
Weitere Angaben zur Dokumentart: | Scientific article |
Nutzungsrechte: | CC BY |
Informationen zu den Nutzungsrechten: | https://creativecommons.org/licenses/by/4.0/ |
Zeitschrift: | Frontiers in anesthesiology 1 |
Seitenzahl oder Artikelnummer: | 990391 |
Verlag: | Frontiers |
Verlagsort: | Lausanne |
Erscheinungsdatum: | 2022 |
ISSN: | 2813-480X |
DOI der Originalveröffentlichung: | 10.3389/fanes.2022.990391 |