dc.description.abstractObjective: We aimed to compare intraocular pressure (IOP) measurements using iCare® PRO rebound tonometry (iCare) and Perkins applanation tonometry (Perkins) in childhood glaucoma subjects and healthy children and the influence of anaesthesia depth, age and corneal thickness. Material: Prospective clinical, case-control study of children who underwent an ophthalmologic examination under general anaesthesia according to our protocol. Children were 45.45 ± 29.76 months old (mean ± SD (standard deviation)). Of all children, 54.05% were female. IOP was taken three times (T1–T3), according to duration and the depth of anaesthesia. The order of measurement alternated, starting with iCare. Agreement between the device measurements was evaluated using Bland–Altman analysis. Results: 53 glaucoma subjects and 22 healthy controls. Glaucoma subjects: IOP measured with iCare was at T1: 27.2 (18.1–33.8), T2: 21.6 (14.8–30.6), T3: 20.4 mmHg (14.5–27.0) and Perkins 17.5 (12.0–23.0), 15.5 (10.5–20.5), 15.0 mmHg (10.5–21.0) (median ± IQR (interquartile range)). Healthy controls: IOP with iCare: T1: 13.3 (11.1–17.0), T2: 10.6 (8.1–12.4), T3: 9.6 mmHg (7.7–11.7) and Perkins 10.3 (8.0–12.0), 7.0 (5.5–10.5), 7.0 mmHg (5.5–8.5) (median ± IQR). The median IOP was statistically significantly higher with iCare than with Perkins (p < 0.001) in both groups. The mean difference (iCare and Perkins) was 6.0 ± 6.1 mmHg for T1–T3, 7.3 at T1, 6.0 at T2, 4.9 mmHg at T3. Conclusion: The IOP was the highest in glaucoma subjects and healthy children at T1 (under sedation), independently of the measurement method. iCare always leads to higher IOP compared to Perkins in glaucoma and healthy subjects, regardless of the duration of anesthesia.en_GB
dc.description.sponsorshipGefördert durch die Deutsche Forschungsgemeinschaft (DFG) - Projektnummer 491381577de
dc.language.isoengde
dc.rightsCC BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleIntraocular pressure measurement in childhood glaucoma under standardized general anaesthesia : the prospective EyeBIS studyen_GB
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-8589-
jgu.type.contenttypeScientific articlede
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleJournal of Clinical Medicinede
jgu.journal.volume11de
jgu.journal.issue10de
jgu.pages.alternative2846de
jgu.publisher.year2022-
jgu.publisher.nameMDPIde
jgu.publisher.placeBaselde
jgu.publisher.issn2077-0383de
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
jgu.publisher.doi10.3390/jcm11102846de
jgu.organisation.rorhttps://ror.org/023b0x485-
jgu.subject.dfgNaturwissenschaftende
Appears in collections:DFG-491381577-G

Files in This Item:
  File Description SizeFormat
Thumbnail
intraocular_pressure_measurem-20230119094817431.pdf1.56 MBAdobe PDFView/Open