Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://doi.org/10.25358/openscience-8589
Autoren: Strzalkowska, Alicja
Pirlich, Nina
Stingl, Julia V.
Schuster, Alexander K.
Rezapour, Jasmin
Wager, Felix M.
Buse, Justus
Hoffmann, Esther M.
Titel: Intraocular pressure measurement in childhood glaucoma under standardized general anaesthesia : the prospective EyeBIS study
Online-Publikationsdatum: 19-Jan-2023
Erscheinungsdatum: 2022
Sprache des Dokuments: Englisch
Zusammenfassung/Abstract: Objective: We aimed to compare intraocular pressure (IOP) measurements using iCare® PRO rebound tonometry (iCare) and Perkins applanation tonometry (Perkins) in childhood glaucoma subjects and healthy children and the influence of anaesthesia depth, age and corneal thickness. Material: Prospective clinical, case-control study of children who underwent an ophthalmologic examination under general anaesthesia according to our protocol. Children were 45.45 ± 29.76 months old (mean ± SD (standard deviation)). Of all children, 54.05% were female. IOP was taken three times (T1–T3), according to duration and the depth of anaesthesia. The order of measurement alternated, starting with iCare. Agreement between the device measurements was evaluated using Bland–Altman analysis. Results: 53 glaucoma subjects and 22 healthy controls. Glaucoma subjects: IOP measured with iCare was at T1: 27.2 (18.1–33.8), T2: 21.6 (14.8–30.6), T3: 20.4 mmHg (14.5–27.0) and Perkins 17.5 (12.0–23.0), 15.5 (10.5–20.5), 15.0 mmHg (10.5–21.0) (median ± IQR (interquartile range)). Healthy controls: IOP with iCare: T1: 13.3 (11.1–17.0), T2: 10.6 (8.1–12.4), T3: 9.6 mmHg (7.7–11.7) and Perkins 10.3 (8.0–12.0), 7.0 (5.5–10.5), 7.0 mmHg (5.5–8.5) (median ± IQR). The median IOP was statistically significantly higher with iCare than with Perkins (p < 0.001) in both groups. The mean difference (iCare and Perkins) was 6.0 ± 6.1 mmHg for T1–T3, 7.3 at T1, 6.0 at T2, 4.9 mmHg at T3. Conclusion: The IOP was the highest in glaucoma subjects and healthy children at T1 (under sedation), independently of the measurement method. iCare always leads to higher IOP compared to Perkins in glaucoma and healthy subjects, regardless of the duration of anesthesia.
DDC-Sachgruppe: 610 Medizin
610 Medical sciences
Veröffentlichende Institution: Johannes Gutenberg-Universität Mainz
Organisationseinheit: FB 04 Medizin
Veröffentlichungsort: Mainz
ROR: https://ror.org/023b0x485
DOI: http://doi.org/10.25358/openscience-8589
Version: Published version
Publikationstyp: Zeitschriftenaufsatz
Weitere Angaben zur Dokumentart: Scientific article
Nutzungsrechte: CC BY
Informationen zu den Nutzungsrechten: https://creativecommons.org/licenses/by/4.0/
Zeitschrift: Journal of Clinical Medicine
11
10
Seitenzahl oder Artikelnummer: 2846
Verlag: MDPI
Verlagsort: Basel
Erscheinungsdatum: 2022
ISSN: 2077-0383
DOI der Originalveröffentlichung: 10.3390/jcm11102846
Enthalten in den Sammlungen:DFG-491381577-G

Dateien zu dieser Ressource:
  Datei Beschreibung GrößeFormat
Miniaturbild
intraocular_pressure_measurem-20230119094817431.pdf1.56 MBAdobe PDFÖffnen/Anzeigen