Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-7847
Authors: Gruszka, Dominik
Herr, Robert
Hely, Hans
Hofmann, Peer
Klitscher, Daniela
Hofmann, Alexander
Rommens, Pol Maria
Title: Impact of different screw designs on durability of fracture fixation : in vitro study with cyclic loading of scaphoid bones
Online publication date: 5-Oct-2022
Year of first publication: 2016
Language: english
Abstract: Purpose The use of new headless compression screws (HCSs) for scaphoid fixation is growing, but the nonunion rate has remained constant. The aim of this study was to compare the stability of fixation resulting from four modern HCSs using a simulated fracture model to determine the optimal screw design(s). Methods We tested 40 fresh-frozen cadaver scaphoids treated with the Acumed Acutrak 2 mini (AA), the KLS Martin HBS2 midi (MH), the Stryker TwinFix (ST) and the Synthes HCS 3.0 with a long thread (SH). The bones with simulated fractures and implanted screws were loaded uniaxially into flexion for 2000 cycles with a constant bending moment of 800 Nmm. The angulation of the fracture fragments was measured continuously. Data were assessed statistically using the univariate ANOVA test and linear regression analysis, and the significance level was set at p < 0.05. Results The median angulation of bone fragments φ allowed by each screw was 0.89° for AA, 1.12° for ST, 1.44° for SH and 2.36° for MH. With regards to linear regression, the most reliable curve was achieved by MH, with a coefficient of determination of R2 = 0.827. This was followed by AA (R2 = 0.354), SH (R2 = 0.247) and ST (R2 = 0.019). Data assessed using an adapted ANOVA model showed no statistically significant difference (p = 0.291) between the screws. Conclusions The continuous development of HCSs has resulted in very comparable implants, and thus, at this time, other factors, such as surgeons’ experience, ease of handling and price, should be taken into consideration.
DDC: 610 Medizin
610 Medical sciences
Institution: Johannes Gutenberg-Universität Mainz
Department: FB 04 Medizin
Place: Mainz
ROR: https://ror.org/023b0x485
DOI: http://doi.org/10.25358/openscience-7847
Version: Published version
Publication type: Zeitschriftenaufsatz
License: CC BY
Information on rights of use: https://creativecommons.org/licenses/by/4.0/
Journal: PLoS one
11
1
Pages or article number: e0145949
Publisher: PLoS
Publisher place: Lawrence, Kan.
Issue date: 2016
ISSN: 1932-6203
Publisher URL: http://dx.doi.org/10.1371/journal.pone.0145949
Publisher DOI: 10.1371/journal.pone.0145949
Appears in collections:DFG-OA-Publizieren (2012 - 2017)

Files in This Item:
  File Description SizeFormat
Thumbnail
impact_of_different_screw_des-20220914005604819.pdf1.62 MBAdobe PDFView/Open