Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://doi.org/10.25358/openscience-7561
Autoren: Tagkalos, Evangelos
Sluis, Pieter Christiaan van der
Uzun, Eren
Berlth, Felix
Staubitz, Julia
Gockel, Ines
Hillegersberg, Richard van
Lang, Hauke
Grimminger, Peter Philipp
Titel: The circular stapled esophagogastric anastomosis in esophagectomy : no differences in anastomotic insufficiency and stricture rates between the 25 mm and 28 mm circular stapler
Online-Publikationsdatum: 16-Aug-2022
Erscheinungsdatum: 2021
Sprache des Dokuments: Englisch
Zusammenfassung/Abstract: Background For patients undergoing an Ivor Lewis esophagectomy with a circular stapled anastomosis, the optimal diameter of the used circular stapler to restore continuity is unknown. The aim of this study was to compare the 25 mm stapled versus the 28 mm stapled esophagogastric anastomosis after Ivor Lewis esophagectomy, focusing on anastomotic insufficiency and postoperative anastomotic strictures. Methods Between February 2008 and June 2019, 349 consecutive patients underwent Ivor Lewis esophagectomy with gastric conduit reconstruction and circular stapled anastomosis. Patient characteristics and postoperative results, such as anastomotic insufficiency rates, postoperative anastomotic stricture rates, time to anastomotic stricture rate, and the number of dilatations, were recorded in a prospective database and analyzed. Results In 222 patients (64%), the 25 mm circular stapler was used and in 127 patients (36%) the 28 mm circular stapler was used. There were no differences in baseline characteristics. Anastomotic insufficiency rates were comparable between the 25 mm (12%) and the 28 mm groups (11%) (p = 0.751). There were no differences between postoperative anastomotic strictures in the 25 mm (14%) and the 28 mm groups (14%) (p = 0.863). Within patients with postoperative anastomotic strictures, a median number of 2 dilatations were observed in each group (p = 0.573) without differences in the time to first diagnosis (p = 0.412). Conclusion There were no differences in anastomotic insufficiency and postoperative anastomotic stricture rates between the 25 mm and the 28 mm circular stapled esophagogastric anastomosis after Ivor Lewis esophagectomy. Both the 25 mm and 28 mm stapler can be safely used to create a circular stapled esophagogastric anastomosis to restore continuity after esophagectomy.
DDC-Sachgruppe: 610 Medizin
610 Medical sciences
Veröffentlichende Institution: Johannes Gutenberg-Universität Mainz
Organisationseinheit: FB 04 Medizin
Veröffentlichungsort: Mainz
ROR: https://ror.org/023b0x485
DOI: http://doi.org/10.25358/openscience-7561
Version: Published version
Publikationstyp: Zeitschriftenaufsatz
Nutzungsrechte: CC BY
Informationen zu den Nutzungsrechten: https://creativecommons.org/licenses/by/4.0/
Zeitschrift: Journal of gastrointestinal surgery
25
Seitenzahl oder Artikelnummer: 2242
2249
Verlag: Springer
Verlagsort: New York, NY
Erscheinungsdatum: 2021
ISSN: 1873-4626
DOI der Originalveröffentlichung: 10.1007/s11605-020-04895-x
Enthalten in den Sammlungen:JGU-Publikationen

Dateien zu dieser Ressource:
  Datei Beschreibung GrößeFormat
Miniaturbild
the_circular_stapled_esophago-20220815145741343.pdf268.58 kBAdobe PDFÖffnen/Anzeigen