Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-5822
Full metadata record
DC FieldValueLanguage
dc.contributor.authorStaubitz, Julia-
dc.contributor.authorSluis, P. C. van der-
dc.contributor.authorBerlth, F.-
dc.contributor.authorWatzka, F.-
dc.contributor.authorDette, F.-
dc.contributor.authorLäßig, A.-
dc.contributor.authorLang, H.-
dc.contributor.authorMusholt, T. J.-
dc.contributor.authorGrimminger, Peter P.-
dc.date.accessioned2021-05-03T09:44:07Z-
dc.date.available2021-05-03T09:44:07Z-
dc.date.issued2020-
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/5831-
dc.description.abstractPURPOSE The robot-assisted approach for Ivor Lewis esophagectomy offers an enlarged, three-dimensional overview of the intraoperative situs. The vagal nerve (VN) can easily be detected, preserved, and intentionally resected below the separation point of the recurrent laryngeal nerve (RLN). However, postoperative vocal cord paresis can result from vagal or RLN injury during radical lymph node dissection, presenting a challenge to the operating surgeon. METHODS From May to August 2019, 10 cases of robot-assisted minimally invasive esophagectomy (RAMIE) with extended 2-field lymphadenectomy, performed at the University Medical Center Mainz, were included in a prospective cohort study. Bilateral intermittent intraoperative nerve monitoring (IONM) of the RLN and VN was performed, including pre- and postoperative laryngoscopy assessment. RESULTS Reliable mean signals of the right VN (2.57 mV/4.50 ms) and the RLN (left 1.24 mV/3.71 ms, right 0.85 mV/3.56 ms) were obtained. IONM facilitated the identification of the exact height of separation of the right RLN from the VN. There were no cases of permanent postoperative vocal paresis. Median lymph node count from the paratracheal stations was 5 lymph nodes. CONCLUSION IONM was feasible during RAMIE. The intraoperative identification of the RLN location contributed to the accuracy of lymph node dissection of the paratracheal lymph node stations. RLN damage and subsequent postoperative vocal cord paresis can potentially be prevented by IONM.en_GB
dc.language.isoengde
dc.rightsCC BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleRecurrent laryngeal nerve monitoring during totally robot-assisted Ivor Lewis esophagectomyen_GB
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-5822-
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleLangenbeck's archives of surgeryde
jgu.journal.volume405de
jgu.pages.start1091de
jgu.pages.end1099de
jgu.publisher.year2020-
jgu.publisher.nameSpringerde
jgu.publisher.placeBerlin u.a.de
jgu.publisher.urihttps://doi.org/10.1007/s00423-020-01990-0de
jgu.publisher.issn1435-2451de
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
jgu.publisher.doi10.1007/s00423-020-01990-0
jgu.organisation.rorhttps://ror.org/023b0x485
Appears in collections:JGU-Publikationen

Files in This Item:
  File Description SizeFormat
Thumbnail
staubitz_j._i.-recurrent_lary-20210423132708598.pdf1.24 MBAdobe PDFView/Open