Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://doi.org/10.25358/openscience-5786
Autoren: Ruemmler, Robert
Ziebart, Alexander
Ott, Thomas
Dirvonskis, Dagmar
Hartmann, Erik Kristoffer
Titel: Flexible fibreoptic intubation in swine : improvement for resident training and animal safety alike
Online-Publikationsdatum: 23-Apr-2021
Erscheinungsdatum: 2020
Sprache des Dokuments: Englisch
Zusammenfassung/Abstract: BACKGROUND Efficient airway management to facilitate tracheal intubation encompasses essential skills in anaesthesiologic and intensive care. The application of flexible fibreoptic intubation in patients with difficult airways has been identified as the recommended method in various international guidelines. However, providing the opportunity to adequately train residents can be challenging. Using large animals for practice during ongoing studies could help to improve this situation, but there is no recent data on fibreoptic intubation in swine available. METHODS Thirty male German landrace pigs were anesthetized, instrumented and randomized into two groups. The animals were either intubated conventionally using direct laryngoscopy or a single-use flexible video-endoscope. The intervention was carried out by providers with 3 months experience in conventional intubation of pigs and a brief introduction into endoscopy. Intubation attempts were supervised and aborted, when SpO2 dropped below 93%. After three failed attempts, an experienced supervisor intervened and performed the intubation. Intubation times and attempts were recorded and analysed. RESULTS Flexible fibreoptic intubation showed a significantly higher success rate in first attempt endotracheal tube placement (75% vs. 47%) with less attempts overall (1.3 ± 0.6 vs. 2.1 ± 1.3, P = 0.043). Conventional intubation was faster (42 s ± 6 s vs. 67 s ± 10s, P < 0.001), but showed a higher complication rate and more desaturation episodes during the trial. CONCLUSIONS Flexible fibreoptic intubation in swine is feasible and appears to be a safer and more accessible method for inexperienced users to learn. This could not only improve resident training options in hospitals with animal research facilities but might also prevent airway complications and needless animal suffering.
DDC-Sachgruppe: 610 Medizin
610 Medical sciences
Veröffentlichende Institution: Johannes Gutenberg-Universität Mainz
Organisationseinheit: FB 04 Medizin
Veröffentlichungsort: Mainz
ROR: https://ror.org/023b0x485
DOI: http://doi.org/10.25358/openscience-5786
Version: Published version
Publikationstyp: Zeitschriftenaufsatz
Nutzungsrechte: CC BY
Informationen zu den Nutzungsrechten: https://creativecommons.org/licenses/by/4.0/
Zeitschrift: BMC anesthesiology
20
Seitenzahl oder Artikelnummer: 206
Verlag: BioMed Central
Verlagsort: London
Erscheinungsdatum: 2020
ISSN: 1471-2253
URL der Originalveröffentlichung: https://doi.org/10.1186/s12871-020-01127-2
DOI der Originalveröffentlichung: 10.1186/s12871-020-01127-2
Enthalten in den Sammlungen:JGU-Publikationen

Dateien zu dieser Ressource:
  Datei Beschreibung GrößeFormat
Miniaturbild
ruemmler_robert-flexible_fibre-20210421120336880.pdf674.81 kBAdobe PDFÖffnen/Anzeigen