Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-3282
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJekle, Carola
dc.date.accessioned2011-02-15T17:24:39Z
dc.date.available2011-02-15T18:24:39Z
dc.date.issued2011
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/3284-
dc.description.abstractIm Rahmen der vorliegenden Arbeit wurden Eignung und Nutzen des „Objective therapy Compliance Measurement“ (OtCMTM)-Systems, einer innovativen Weiterentwicklung im Bereich der elektronischen Compliance-Messung, untersucht. Unter experimentellen Bedingungen wurden Funktionalität und Verlässlichkeit der elektronischen OtCMTM-Blisterpackungen überprüft, um deren Eignung für den klinischen Einsatz zu zeigen. Funktionalität (≥90% lesbare Blister), Richtigkeit (≤2% Fehler) und Robustheit waren bei den OtCMTM-Blistern der Version 3 gegeben, nachdem die Fehler der Versionen 1 und 2 in Zusammenarbeit mit dem Hersteller TCG identifiziert und eliminiert worden waren. Der als Alternative zu den elektronischen Blistern für die Verpackung von klinischen Prüfmustern entwickelte OtCMTM e-Dispenser wurde bezüglich Funktionalität und Anwenderfreundlichkeit in einer Pilotstudie untersucht. Dabei wurde ein Optimierungsbedarf festgestellt. In einer klinischen Studie wurde das OtCMTM-System mit dem als „Goldstandard“ geltenden MEMS® verglichen. Vergleichskriterien waren Datenqualität, Akzeptanz und Anwenderfreundlichkeit, Zeitaufwand bei der Bereitstellung der Medikation und Datenauswertung, sowie Validität. Insgesamt 40 Patienten, die mit Rekawan® retard 600mg behandelt wurden, nahmen an der offenen, randomisierten, prospektiven Studie teil. Das OtCMTM-System zeigte sich bezüglich Validität, Akzeptanz und Anwenderfreundlichkeit mit MEMS® vergleichbar. Eine erwartete Zeitersparnis wurde mit dem OtCMTM-System gegenüber MEMS® nicht erreicht. Vorteile des OtCMTM-Systems sind eine höhere Datenqualität und die Möglichkeit zum Einsatz in der Telemedizin.de_DE
dc.description.abstractWithin the scope of this work suitability and benefit of the “Objective therapy Compliance Measurement”-(OtCM-)system, an innovation in the field of electronic compliance monitoring, were examined. Functionality and reliability of the OtCM-blister packages were verified under experimental conditions in order to show their eligibility for usage in clinical practice. Version 3 of the OtCM-blister packages showed functionality (≥90% readable devices), accuracy (≤2% false registrations) and robustness after failures of previous versions had been identified and eliminated in cooperation with the producer TCG. The OtCM e-Dispenser, an alternative to the electronic blister packages, was designed for packaging of clinical trial supplies. During a pilot study functionality and usability of the e-Dispenser were examined and a need for improvement was observed. The OtCM-system was compared to the “gold-standard” MEMS® in terms of quality of data, validity, acceptance, usability and expenditure of time for preparation and data evaluation. 40 patients who were treated with Rekawan® retard 600mg participated in the open, randomised, prospective, clinical study. The OtCM-system revealed equal validity, acceptance and usability to MEMS®. An expected time saving could not be shown compared to MEMS®. Advantages of the OtCM-system are higher quality of data and the possibility of use for telemedicine purposes.en_GB
dc.language.isoger
dc.rightsInCopyrightde_DE
dc.rights.urihttps://rightsstatements.org/vocab/InC/1.0/
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleDas OtCM-System zur elektronischen Compliance-Messung : Qualitätsuntersuchung der OtCM-Blister und e-Dispenser ; Validierung und Nutzenevaluation im Vergleich mit MEMSde_DE
dc.typeDissertationde_DE
dc.identifier.urnurn:nbn:de:hebis:77-26675
dc.identifier.doihttp://doi.org/10.25358/openscience-3282-
jgu.type.dinitypedoctoralThesis
jgu.type.versionOriginal worken_GB
jgu.type.resourceText
jgu.description.extent147 S.
jgu.organisation.departmentFB 09 Chemie, Pharmazie u. Geowissensch.-
jgu.organisation.year2011
jgu.organisation.number7950-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.organisation.placeMainz-
jgu.subject.ddccode610
opus.date.accessioned2011-02-15T17:24:39Z
opus.date.modified2011-02-28T09:32:33Z
opus.date.available2011-02-15T18:24:39
opus.subject.dfgcode00-000
opus.subject.otherelektronische Compliance-Messung , elektronische Blister , OtCM-System , Validitätde_DE
opus.subject.otherelectronic compliance monitoring , electronic blister packages , OtCM-system , validityen_GB
opus.organisation.stringFB 09: Chemie, Pharmazie und Geowissenschaften: Institut für Pharmaziede_DE
opus.identifier.opusid2667
opus.institute.number0908
opus.metadataonlyfalse
opus.type.contenttypeDissertationde_DE
opus.type.contenttypeDissertationen_GB
jgu.organisation.rorhttps://ror.org/023b0x485
Appears in collections:JGU-Publikationen

Files in This Item:
  File Description SizeFormat
Thumbnail
2667.pdf3.98 MBAdobe PDFView/Open