Comparison of rebound tonometry, Perkins applanation tonometry and ocular response analyser in mucopolysaccharidosis patients

dc.contributor.authorWasielica-Poslednik, Joanna
dc.contributor.authorButsch, Christina
dc.contributor.authorLampe, Christina
dc.contributor.authorElflein, Heike
dc.contributor.authorLamparter, Julia
dc.contributor.authorWeyer, Veronika
dc.contributor.authorPitz, Susanne
dc.date.accessioned2022-07-12T07:17:51Z
dc.date.available2022-07-12T07:17:51Z
dc.date.issued2015
dc.description.abstractAims To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA) Methods MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and retrospectively analyzed in this study. Results 17 patients fulfilled the inclusion criterion. In all 17 patients IOP measurements were performed with RT (34 eyes) and ORA (33 eyes), while PAT measurement was possible in only 12 (24 eyes) patients. The RT, corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated intraocular pressure (IOPg) differed relevantly from IOP assessed with PAT. Corneal clouding in MPS patients correlated positively with PAT, RT and IOPg (r = 0.3, 0.5, and 0.5 respectively), but not with IOPcc (r = 0.07). The MPS-related corneal clouding correlated positively with biomechanical corneal parameters assessed with ORA: corneal hysteresis (r = 0.77) and corneal resistance factor (r = 0.77) either. Conclusions RT and ORA measurements were tolerated better than applanation tonometry in MPS patients. IOP measurements assessed with RT and ORA differed relevantly from PAT. Corneal-compensated IOP assessed with ORA seems to be less affected by the MPS-related corneal clouding than applanation or rebound tonometry. RT and ORA measurements should be preferred for IOP assessment in patients with MPS.en_GB
dc.description.sponsorshipDFG, Open Access-Publizieren Universität Mainz / Universitätsmedizinde
dc.identifier.doihttp://doi.org/10.25358/openscience-7358
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/7372
dc.language.isoengde
dc.rightsCC-BY-4.0*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleComparison of rebound tonometry, Perkins applanation tonometry and ocular response analyser in mucopolysaccharidosis patientsen_GB
dc.typeZeitschriftenaufsatzde
jgu.journal.issue8de
jgu.journal.titlePLoS onede
jgu.journal.volume10de
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.alternativee0133586de
jgu.publisher.doi10.1371/journal.pone.0133586de
jgu.publisher.issn1932-6203de
jgu.publisher.namePLoSde
jgu.publisher.placeLawrence, Kan.de
jgu.publisher.urihttp://dx.doi.org/10.1371/journal.pone.0133586de
jgu.publisher.year2015
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610de
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTextde
jgu.type.versionPublished versionde
opus.affiliatedWasielica-Poslednik, Joanna
opus.affiliatedElflein, Heike
opus.affiliatedLamparter, Julia
opus.affiliatedPitz, Susanne
opus.date.modified2017-05-12T09:11:42Z
opus.identifier.opusid56519
opus.institute.number0446
opus.metadataonlyfalse
opus.organisation.stringFB 04: Medizin: Augenklinik und Poliklinikde_DE
opus.subject.dfgcode00-000
opus.type.contenttypeKeinede_DE
opus.type.contenttypeNoneen_EN

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
comparison_of_rebound_tonomet-20220710211533249.pdf
Size:
833.08 KB
Format:
Adobe Portable Document Format
Description: