Safety profile and complication rates in emergency off-label use of tirofiban in interventional neuroradiology : an observational dual center study

dc.contributor.authorBrockmann, Carolin
dc.contributor.authorDillinger, Daniel
dc.contributor.authorMpotsaris, Anastasios
dc.contributor.authorSpreer, Annette
dc.contributor.authorMaus, Volker
dc.contributor.authorWaldeck, Stephan
dc.contributor.authorOthman, Ahmed E.
dc.contributor.authorAltmann, Sebastian
dc.contributor.authorRingel, Florian
dc.contributor.authorKerz, Thomas
dc.contributor.authorBrockmann, Marc A.
dc.date.accessioned2023-01-20T16:47:08Z
dc.date.available2023-01-20T16:47:08Z
dc.date.issued2022
dc.description.abstractPurpose Tirofiban has been approved for the treatment of acute coronary syndrome. Meanwhile, tirofiban is frequently applied in emergency situations in interventional neuroradiology (INR). The objective of this study was to analyze the risk profile for the off-label use of tirofiban in INR patients. Methods Data of 86 patients, who underwent neurointerventional therapy and were treated with tirofiban at 2 neuroendovascular centers between January 2016 and July 2017 were retrospectively analyzed. Despite off-label use, recent stroke (< 30 days), recent hemorrhage, thrombocytopenia (< 150,000/µl), activated partial thromboplastin time (aPTT) > 1.3-fold, internation normalised ratio (INR) < 1.5, severe liver insufficiency (Child-Pugh C), and preceding intravenous thrombolysis were considered as contraindications. Results Median patient age was 62 years (range 26–88 years). Patients received tirofiban for extracranial (n = 35) or intracranial stenting (n = 35), coiling of ruptured cerebral aneurysms (n = 6), continuous intra-arterial nimodipine infusion via microcatheters for subarachnoid hemorrhage (SAH)-related vasospasm (n = 5), or thrombotic complications during neuroendovascular procedures (n = 5). The desired effect of preventing thrombotic complications when applying tirofiban off-label was achieved in 81 of 86 patients (94.2%). Relevant tirofiban-associated complications occurred in 14 patients (16.3%), of which 9 patients received i.v. thrombolysis for treatment of acute ischemic stroke shortly before starting therapy with tirofiban. Of the 86 patients 12 died, while the overall tirofiban-related mortality was 2.3% (2 patients died due to ICH). Logistic regression analysis revealed age to be the only parameter significantly associated with development of tirofiban-associated complications (p = 0.026). Conclusion Whereas the safety profile of tirofiban when applied off-label in INR is acceptable, the highest risk for relevant tirofiban-associated complications is observed in older patients treated by emergency stenting for acute stroke.en_GB
dc.description.sponsorshipGefördert durch die Deutsche Forschungsgemeinschaft (DFG) - Projektnummer 491381577
dc.identifier.doihttp://doi.org/10.25358/openscience-8417
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/8433
dc.language.isoeng
dc.rightsCC-BY-4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleSafety profile and complication rates in emergency off-label use of tirofiban in interventional neuroradiology : an observational dual center studyen_GB
dc.typeZeitschriftenaufsatzde_DE
jgu.apc.pricePAR-Fee
jgu.apc.transformationcontractSpringer (DEAL)
jgu.dfg.year2022
jgu.journal.titleClinical neuroradiology
jgu.journal.volumeVersion of Record (VoR)
jgu.organisation.departmentFB 04 Medizinde_DE
jgu.organisation.nameJohannes Gutenberg-Universität Mainzde_DE
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.publisher.doi10.1007/s00062-022-01223-5
jgu.publisher.issn1869-1447
jgu.publisher.nameUrban & Vogel
jgu.publisher.placeMünchen
jgu.publisher.year2022
jgu.rights.accessrightsopenAccessen_GB
jgu.subject.ddccode610
jgu.subject.dfgLebenswissenschaftende_DE
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTexten_GB
jgu.type.versionPublished versionen_GB

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
safety_profile_and_complicati-20221124154858723.pdf
Size:
484.35 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections