The working angle in low-abrasive air polishing has an influence on gingival damage : an ex vivo porcine model

dc.contributor.authorWeusmann, Jens
dc.contributor.authorDeschner, James
dc.contributor.authorKeppler, Christopher
dc.contributor.authorImber, Jean-Claude
dc.contributor.authorCores Ziskoven, Pablo
dc.contributor.authorSchumann, Sven
dc.date.accessioned2024-01-03T10:38:37Z
dc.date.available2024-01-03T10:38:37Z
dc.date.issued2023
dc.description.abstractObjectives To investigate the influence of instrumentation angle during low-abrasive air polishing (LAA) on the oral gingiva using an ex vivo porcine model. Material and methods Six tissue samples from each of 14 porcine mandibles were randomly selected and instrumented. Two different LAA powders (glycine 25 μm, tagatose 15 μm) were investigated. An application angle of either 30–60° or 90° was selected. Gingival specimens from different mandibles served as untreated references. Gingival biopsies were examined by scanning electron microscopy and paraffin histology for tissue destruction using a five-level scale. Results LAA caused significantly less tissue damage at a 90° angle than at a 30–60° angle. This effect was seen in both the glycine-based powder arms (p = 0.002, p = 0.046) and the tagatose-based powder arms (p = 0.003, p = 0.011). However, at identical working angles, the two powders did not show significant differences in terms of gingival erosion (p = 0.79 and p = 0.57; p = 0.91 and p = 0.78, respectively). Conclusions LAA may cause less tissue damage at an application angle of 90°. Consequently, it seems advisable to air-polish the soft tissue as perpendicularly as possible. Additionally, glycine and tagatose LAA powders do not seem to differ in concern of soft tissue damage. Clinical relevance Within the limitations of this ex vivo animal model, this study argues for an application that is as close as possible to the 90° angle intending to minimize soft tissue damage. Manufacturer specifications, however, mainly request applications deviating from the right angle. In order to work in interdental areas using LAA safely, the use of subgingival nozzles might be considered.en_GB
dc.identifier.doihttp://doi.org/10.25358/openscience-9839
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/9857
dc.language.isoengde
dc.rightsCC-BY-4.0*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleThe working angle in low-abrasive air polishing has an influence on gingival damage : an ex vivo porcine modelen_GB
dc.typeZeitschriftenaufsatzde
jgu.journal.titleClinical oral investigationsde
jgu.journal.volume27de
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.nameJohannes Gutenberg-Universität Mainz
jgu.organisation.number2700
jgu.organisation.placeMainz
jgu.organisation.rorhttps://ror.org/023b0x485
jgu.pages.end6207de
jgu.pages.start6199de
jgu.publisher.doi10.1007/s00784-023-05236-3de
jgu.publisher.issn1436-3771de
jgu.publisher.nameSpringerde
jgu.publisher.placeBerlin u.a.de
jgu.publisher.year2023
jgu.rights.accessrightsopenAccess
jgu.subject.ddccode610de
jgu.subject.dfgLebenswissenschaftende
jgu.type.dinitypeArticleen_GB
jgu.type.resourceTextde
jgu.type.versionPublished versionde

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
the_working_angle_in_lowabras-20231215111430037.pdf
Size:
1.7 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.57 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections