Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://doi.org/10.25358/openscience-9833
Autoren: Grauhan, Nils F.
Grünebach, Natascha
Brockstedt, Lavinia
Sanner, Antoine
Feiweier, Thorsten
Schöffling, Vanessa
Brockmann, Marc A.
Othman, Ahmed E.
Titel: Reduction of distortion artifacts in brain MRI using a field map-based correction technique in diffusion-weighted imaging : a prospective study
Online-Publikationsdatum: 16-Jan-2024
Erscheinungsdatum: 2023
Sprache des Dokuments: Englisch
Zusammenfassung/Abstract: Purpose The aim of this study was to evaluate the image quality and feasibility of a field map-based technique to correct for susceptibility-induced geometric distortions which are typical for diffusion EPI brain imaging. Methods We prospectively included 52 patients during clinical routine in this single-center study. All scans were performed on a 3T MRI. Patients’ indications for MRI mainly consisted of suspected stroke due to the clinical presentation. For the morphological comparison of the corrected and uncorrected EPI diffusion, three experienced radiologists assessed the image quality of the sequences in a blinded and randomized fashion using a Likert scale (1 being poor; 5 being excellent). To ensure comparability of the two methods, an additional quantitative analysis of the apparent diffusion coefficient (ADC) was performed. Results Corrected EPI diffusion was rated significantly superior in all the selected categories: overall level of artifacts (p < 0.001), degree of distortion at the frontal, temporal, occipital and brainstem levels (p < 0.001), conspicuousness of ischemic lesions (p < 0.001), image quality (p < 0.001), naturality (p < 0.001), contrast (p < 0.001), and diagnostic confidence (p < 0.001). Conclusion Corrected EPI diffusion offers a significant reduction of geometric distortion in all evaluated brain regions and an improved conspicuousness of ischemic lesions. Image quality, overall artifacts, naturality, contrast and diagnostic confidence were also rated superior in comparison to uncorrected EPI diffusion.
DDC-Sachgruppe: 610 Medizin
610 Medical sciences
Veröffentlichende Institution: Johannes Gutenberg-Universität Mainz
Organisationseinheit: FB 04 Medizin
Veröffentlichungsort: Mainz
ROR: https://ror.org/023b0x485
DOI: http://doi.org/10.25358/openscience-9833
Version: Published version
Publikationstyp: Zeitschriftenaufsatz
Nutzungsrechte: CC BY
Informationen zu den Nutzungsrechten: https://creativecommons.org/licenses/by/4.0/
Zeitschrift: Clinical neuroradiology
Version of Record (VoR)
Verlag: Urban & Vogel,
Verlagsort: München
Erscheinungsdatum: 2023
ISSN: 1869-1447
DOI der Originalveröffentlichung: 10.1007/s00062-023-01338-3
Enthalten in den Sammlungen:DFG-491381577-H

Dateien zu dieser Ressource:
  Datei Beschreibung GrößeFormat
Miniaturbild
reduction_of_distortion_artif-20231215100111132.pdf659.81 kBAdobe PDFÖffnen/Anzeigen