dc.description.abstractTransfemoral aortic valve replacement (TAVR) has become a standard therapeutic option for patients with symptomatic severe aortic stenosis. Special anatomies can pose distinct challenges for vascular access and later closure of the access site, for example, in preoperated patients. Here, we elucidate a case of transfemoral TAVR with vascular access by direct puncture of an aorto-bifemoral bypass graft and illustrate the feasibility of vascular closure by an anchored collagen-plug vascular closure device (Teleflex MANTA®).en_GB
dc.language.isoengde
dc.rightsCC BY-NC-ND*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titlePercutaneous puncture of an aorto-bifemoral bypass graft and successful closure with MANTA® device in transfemoral TAVRen_GB
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-7725-
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleEchocardiographyde
jgu.journal.volume38de
jgu.journal.issue3de
jgu.pages.start506de
jgu.pages.end507de
jgu.publisher.year2021-
jgu.publisher.nameWiley-Blackwellde
jgu.publisher.placeOxford u.a.de
jgu.publisher.issn1540-8175de
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
jgu.publisher.doi10.1111/echo.15016de
jgu.organisation.rorhttps://ror.org/023b0x485-
Appears in collections:JGU-Publikationen

Files in This Item:
  File Description SizeFormat
Thumbnail
percutaneous_puncture_of_an_a-20220905130037040.pdf530.54 kBAdobe PDFView/Open