Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-7602
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlbrecht, K.-
dc.contributor.authorLotz, Johannes-
dc.contributor.authorFrommer, Lara-
dc.contributor.authorLackner, Karl J.-
dc.contributor.authorKahaly, George J.-
dc.date.accessioned2022-08-23T08:34:11Z-
dc.date.available2022-08-23T08:34:11Z-
dc.date.issued2021-
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/7616-
dc.description.abstractPurpose Vitamin D (VitD) is a pleiotropic hormone with effects on a multitude of systems and metabolic pathways. Consequently, the relevance of a sufficiently high VitD serum level becomes self-evident. Methods A rapid immunofluorescence assay designed for the point-of-care measurement of serum VitD3 solely was tested. Inter- and intra-assay validation, double testing and result comparison with a standardized laboratory method were performed. Results An overall linear correlation of r = 0.89 (Pearson, 95% CI 0.88–0.92, p < 0.01) between the point of care and the conventional reference assay was registered. Accuracy and precision were of special interest at cut-points (10 ng/ml [mean deviation 1.7 ng/ml, SD 1.98 ng/ml, SE 0.16 ng/ml], 12 ng/ml [MD 0.41, SD 1.89, SE 0.19] and 30 ng/ml [MD − 1.11, SD 3.89, SE 0.35]). Only a slight deviation was detected between the two assays when using fresh (r = 0.91, 95% CI 0.86–0.94, p < 0.01) and frozen serum samples (r = 0.86, 0.82–0.89, p < 0.01). Results remained steady when samples were frozen several times. Inter- and intra-assay validation according to the CLSI protocol as well as multiuser testing showed stable results. Conclusion This novel, innovative, and controlled study indicates that the evaluated rapid point of care VitD assay is reliable, accurate, and suited for clinical practice.en_GB
dc.language.isoengde
dc.rightsCC BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleA rapid point-of-care assay accurately measures vitamin Den_GB
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-7602-
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleJournal of endocrinological investigationde
jgu.journal.volume44de
jgu.pages.start2485de
jgu.pages.end2492de
jgu.publisher.year2021-
jgu.publisher.nameSpringerde
jgu.publisher.placeS. l.de
jgu.publisher.issn1720-8386de
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
jgu.publisher.doi10.1007/s40618-021-01575-8de
jgu.organisation.rorhttps://ror.org/023b0x485-
Appears in collections:JGU-Publikationen

Files in This Item:
  File Description SizeFormat
Thumbnail
a_rapid_pointofcare_assay_acc-20220822142554591.pdf1.53 MBAdobe PDFView/Open