Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-7128
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKriege, Marc-
dc.contributor.authorAlflen, Christian-
dc.contributor.authorNoppens, Rüdiger-
dc.date.accessioned2022-06-13T09:48:45Z-
dc.date.available2022-06-13T09:48:45Z-
dc.date.issued2017
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/7142-
dc.description.abstractPurpose It is generally accepted that using a video laryngoscope is associated with an improved visualization of the glottis. However, correctly placing the endotracheal tube might be challenging. Channeled video laryngoscopic blades have an endotracheal tube already pre-loaded, allowing to advance the tube once the glottis is visualized. We hypothesized that use of a channel blade with pre-loaded endotracheal tube results in a faster intubation, compared to a curved Macintosh blade video laryngoscope. Methods After ethical approval and informed consent, patients were randomized to receive endotracheal Intubation with either the King Vision® video laryngoscope with curved blade (control) or channeled blade (channeled). Success rate, evaluation of the glottis view (percentage of glottic opening (POGO), Cormack&Lehane (C&L)) and intubating time were evaluated. Results Over a two-month period, a total of 46 patients (control n = 23; channeled n = 23) were examined. The first attempt success rates were comparable between groups (control 100% (23/23) vs. channeled 96% (22/23); p = 0.31). Overall intubation time was significantly shorter with control (median 40 sec; IQR [24–58]), compared to channeled (59 sec [40–74]; p = 0.03). There were no differences in glottis visualization between groups. Conclusion Compared with the King Vision channeled blade, time for tracheal intubation was shorter with the control group using a non-channeled blade. First attempt success and visualization of the glottis were comparable. These data do not support the hypothesis that a channeled blade is superior to a curved video laryngoscopic blade without tube guidance.en_GB
dc.description.sponsorshipDFG, Open Access-Publizieren Universität Mainz / Universitätsmedizinde
dc.language.isoengde
dc.rightsCC BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleUsing King Vision video laryngoscope with a channeled blade prolongs time for tracheal intubation in different training levels, compared to non-channeled bladeen_GB
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-7128-
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titlePLoS onede
jgu.journal.volume12de
jgu.journal.issue8de
jgu.pages.alternativee0183382de
jgu.publisher.year2017-
jgu.publisher.namePLoSde
jgu.publisher.placeSan Francisco, California, USde
jgu.publisher.urihttp://dx.doi.org/10.1371/journal.pone.0183382de
jgu.publisher.issn1932-6203de
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
opus.date.modified2018-11-29T11:39:20Z
opus.subject.dfgcode00-000
opus.organisation.stringFB 04: Medizin: Klinik für Anästhesiologiede_DE
opus.identifier.opusid57930
opus.institute.number0418
opus.metadataonlyfalse
opus.type.contenttypeKeinede_DE
opus.type.contenttypeNoneen_EN
opus.affiliatedKriege, Marc
opus.affiliatedAlflen, Christian
jgu.publisher.doi10.1371/journal.pone.0183382de
jgu.organisation.rorhttps://ror.org/023b0x485
Appears in collections:DFG-OA-Publizieren (2012 - 2017)

Files in This Item:
  File Description SizeFormat
Thumbnail
using_king_vision_video_laryn-20220612153739948.pdf9.95 MBAdobe PDFView/Open