Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-6465
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPayne, Emily Sarah-
dc.date.accessioned2022-01-12T10:01:19Z-
dc.date.available2022-01-12T10:01:19Z-
dc.date.issued2022-
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/6475-
dc.description.abstractClot-retrieval failure and embolism in new territories (ENT) are complications reducing the ecacy ofmechanical thrombectomy (MT). Reasons for these problems are clot abruption during stent retrieverretraction into the cylindrical tip of a standard distal access catheter (DAC), and antegrade blood owduring retrieval. To overcome these complications, a funnel-shaped tip catheter model was developed andtested. Using an experimental in vitro setup, this study compared the ecacy of a funnel-shaped tip witha standard cylindrical tip in combination with different clot compositions. Mechanical thrombectomy wasperformed 80 times for each tip, using two stent retrievers (Trevo XP ProVue 3/20 mm and 4/20 mm) andfour different clot types (mechanical vs. static preparation, 0-24h vs. 72h clot aging times). Signicantlyhigher rst-pass recanalization rates were observed for the funnel-shaped tip, which reached 70.0% vs.30.0% for the standard tip (absolute difference, 32; relative difference 20.0%, P < 0.05), regardless of theclot type and stent retriever. Recanalization could be increased using brin-rich mechanical clots vs. clotsprepared under static conditions, as well as 0-24h vs. 72h aged clots, respectively. The extended in vitro-experiments veried the usability of the recently patented funnel-shaped DAC, hereby implementing next-level in vivo-experiments.en_GB
dc.language.isoengde
dc.rightsCC BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleIn vitro-Testung eines Kathetermodells mit einer trichterförmig erweiterten Spitze zur Reduktion von Thrombusmigration unter Verwendung von verschiedenen Thrombuskompositionen für die mechanische Thrombektomiede_DE
dc.titleIn vitro Testing of a Funnel-tip Catheter Model to Decrease Clot Migration and to Evaluate Clot Effects in Mechanical Thrombectomyen_GB
dc.typeDissertationde
dc.identifier.urnurn:nbn:de:hebis:77-openscience-c1875880-959f-4c22-9980-6d3ad4debf461-
dc.identifier.doihttp://doi.org/10.25358/openscience-6465-
jgu.type.dinitypedoctoralThesisen_GB
jgu.type.versionOriginal workde
jgu.type.resourceTextde
jgu.date.accepted2021-11-05-
jgu.description.extent110 Seiten, Illustrationende
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.publisher.year2021-
jgu.publisher.nameResearch Square Preprint Version (not published yet)de
jgu.publisher.urihttps://www.researchgate.net/publication/349418192_In_vitro_testing_of_a_funnel-tip_catheter_model_to_decrease_clot_migration_and_to_evaluate_clot_effects_in_mechanical_thrombectomyde
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
jgu.organisation.rorhttps://ror.org/023b0x485
Appears in collections:JGU-Publikationen

Files in This Item:
  File Description SizeFormat
Thumbnail
payne_emily_sarah-in_vitro_testi-20211106025807579.pdfDoctoral Thesis6.4 MBAdobe PDFView/Open