Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-5852
Full metadata record
DC FieldValueLanguage
dc.contributor.authorStaedt, Henning-
dc.contributor.authorMally, Eva-
dc.contributor.authorScheller, Herbert-
dc.contributor.authorWentaschek, Stefan-
dc.contributor.authorKämmerer, Peer Wolfgang-
dc.contributor.authorKasaj, Adrian-
dc.contributor.authorDevigus, Alessandro-
dc.contributor.authorLehmann, Karl Martin-
dc.date.accessioned2021-05-10T07:01:53Z-
dc.date.available2021-05-10T07:01:53Z-
dc.date.issued2021-
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/5861-
dc.description.abstractINTRODUCTION This study evaluated the reproducibility of electronic color determination system evaluations of the marginal gingiva, which could be important for adhesive cervical fillings or prosthetic restorations that imitate the gingiva. MATERIAL AND METHODS In 50 subjects, the L*, a*, and b* color coordinates were evaluated five times at a point in the marginal area of a central incisor using different electronic color determination systems: (SP) Shadepilot, (ES) Easyshade, (CE) Crystaleye, and (SV) X-Rite. The mean color difference (ΔE) and its standard deviation between the five measurements from each participant were calculated separately for each device. Further ICC for interdevice reliability was determined. RESULTS The L*, a*, and b* color coordinates and ΔE values differed significantly among the systems (p < 0.001). Within each patient and measurement system, ΔE ranged from 1.4 to 3.2 (SD 1.1–2.5), L* from 2.6 to 5.7 (SD 2.6–5.7), a* from 11.9 to 21.3 (SD 3.6–3.9), and b* from 15.1 to 28.9 (SD 1.7–4.3). Interdevice reliability ranged between 0.675 and 0.807. CONCLUSIONS Color determination of the marginal gingiva using the electronic tooth color determination systems tested herein showed limited reproducibility. The results obtained with the different measurement systems differed enormously. CLINICAL RELEVANCE These results show that the electronic color measurement devices tested allow no high reproducible determination of color coordinates of the marginal gingiva.en_GB
dc.language.isoengde
dc.rightsCC BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleThe reproducibility of electronic color measurements of the marginal gingivaen_GB
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-5852-
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleClinical oral investigationsde
jgu.journal.volume25de
jgu.pages.start145de
jgu.pages.end150de
jgu.publisher.year2021-
jgu.publisher.nameSpringerde
jgu.publisher.placeBerlin u.a.de
jgu.publisher.urihttps://doi.org/10.1007/s00784-020-03345-xde
jgu.publisher.issn1436-3771de
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
jgu.publisher.doi10.1007/s00784-020-03345-x
jgu.organisation.rorhttps://ror.org/023b0x485
Appears in collections:JGU-Publikationen

Files in This Item:
  File Description SizeFormat
Thumbnail
staedt_henning-the_reproducib-20210427133003385.pdf2.74 MBAdobe PDFView/Open