Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-1333
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMühlfeld, Lukas
dc.date.accessioned2012-04-10T10:24:58Z
dc.date.available2012-04-10T12:24:58Z
dc.date.issued2012
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/1335-
dc.description.abstractZiel dieser Arbeit ist die Untersuchung der Einflüsse von Blister-Design und Folienqualität auf die Funktionalität von Blisterverpackungen. Hierzu werden analytische Methoden mittels Interferometrie, IR-Spektroskopie, Betarückstreuverfahren, Wirbelstromverfahren und Impedanzspektroskopie entwickelt, die zur quantitativen Bestimmung von Heißsiegellacken und Laminatbeschichtungen von Aluminium-Blisterfolien geeignet sind. Ein Vergleich der Methoden zeigt, dass sich das Betarückstreuverfahren, die Interferometrie und IR-Messungen für die Heißsiegellackbestimmung, die Interferometrie und das Wirbelstromverfahren für die Bestimmung von Kunststofflaminaten eignen.rnIm zweiten Abschnitt der Arbeit werden Einflüsse des Heißsiegellack-Flächengewichtes von Deckfolien auf die Qualität von Blisterverpackungen untersucht. Mit Zunahme des Flächengewichtes zeigt sich eine Erhöhung der Siegelnahtfestigkeit aber auch der Wasserdampfdurchlässigkeit von Blistern. Die untersuchten Heißsiegellacke zeigen Permeationskoeffizienten vergleichbar mit Polyvinylchlorid. In Untersuchungen zur Siegelprozessvalidität zeigt das Heißsiegellack-Flächengewicht nur geringfügige Auswirkungen auf diese. rnIm dritten Abschnitt der Arbeit werden Einflüsse des Blister-Designs auf die Benutzerfreundlichkeit von Blisterverpackungen durch eine Handlingstudie untersucht. Variationen der Öffnungskräfte von Durchdrück-Blistern wirken sich deutlich auf die Bewertungen der Blister durch die Probanden aus. Während die meisten Probanden alle getesteten Durchdrück-Blister innerhalb der Testdauer von 4 Minuten öffnen können (>84%), treten beim Peel-Blister und Peel-off-push-through-Blister deutlich mehr Handlingprobleme auf. Die Handlingprobleme korrelieren mit dem Alter, der Lebenssituation, der gesundheitlichen Verfassung und der Sehfähigkeit der Probanden. rnde_DE
dc.description.abstractAnalytical methods, suitable for quantification of heat seal lacquers and laminate layers of aluminium blister foils in routine quality control were developed using interferometric, infrared spectroscopic, beta backscatter, impedance spectroscopic and eddy current techniques. Regarding parameters required for validation, beta backscatter, interferometric and IR measurements were suitable for determination of heat seal lacquers, whereas interferometric and eddy current measurements were suitable for determination of polymer laminates.rnAdditionally, the influences of heat seal lacquer grammage on the quality of blister packaging were investigated. Higher grammages caused an increase of sealed seam strength and water vapor permeability of blisters. The permeability coefficients of the investigated lacquers were similar to the coefficients of poly vinyl chloride. Grammage showed only slight effects on sealing process validity.rnBesides heat seal lacquer investigations the usability of several blister designs were examined in a handling study. Different opening forces of push through blisters were clearly realized by participants. However, most participants (>84%) could open each of these within 4 minutes, whereas many failed to open peel (30 %) and peel-off push through blisters (44 %). Medical condition, vision, age and life situation of participants correlated with utilization problems.rnen_GB
dc.language.isoger
dc.rightsInCopyrightde_DE
dc.rights.urihttps://rightsstatements.org/vocab/InC/1.0/
dc.subject.ddc500 Naturwissenschaftende_DE
dc.subject.ddc500 Natural sciences and mathematicsen_GB
dc.titleEinflüsse von Folienqualität und Blister-Design auf die Funktionalität von Blisterverpackungende_DE
dc.typeDissertationde_DE
dc.identifier.urnurn:nbn:de:hebis:77-30766
dc.identifier.doihttp://doi.org/10.25358/openscience-1333-
jgu.type.dinitypedoctoralThesis
jgu.type.versionOriginal worken_GB
jgu.type.resourceText
jgu.description.extent252 S.
jgu.organisation.departmentFB 09 Chemie, Pharmazie u. Geowissensch.-
jgu.organisation.year2011
jgu.organisation.number7950-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.organisation.placeMainz-
jgu.subject.ddccode500
opus.date.accessioned2012-04-10T10:24:58Z
opus.date.modified2012-04-10T10:47:13Z
opus.date.available2012-04-10T12:24:58
opus.subject.dfgcode00-000
opus.organisation.stringFB 09: Chemie, Pharmazie und Geowissenschaften: Institut für Pharmaziede_DE
opus.identifier.opusid3076
opus.institute.number0908
opus.metadataonlyfalse
opus.type.contenttypeDissertationde_DE
opus.type.contenttypeDissertationen_GB
jgu.organisation.rorhttps://ror.org/023b0x485
Appears in collections:JGU-Publikationen

Files in This Item:
  File Description SizeFormat
Thumbnail
3076.pdf6.8 MBAdobe PDFView/Open