Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-9436
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSagheb, Kawe-
dc.contributor.authorGörgen, Carolin-Isabel-
dc.contributor.authorDöll, Stefan-
dc.contributor.authorSchmidtmann, Irene-
dc.contributor.authorWentaschek, Stefan-
dc.date.accessioned2023-08-24T10:54:15Z-
dc.date.available2023-08-24T10:54:15Z-
dc.date.issued2023-
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/9454-
dc.description.abstractPurpose An experimental approach was designed to measure the preload force, the coefficient of friction and the component of the tightening torque that is needed to surmount the thread-friction in an implant–abutment–screw complex that includes a carbon-coated screw. With the determined preload values the coefficient of friction was calculated. Methods 25 unused complexes, containing an implant, an abutment and a carbon-coated titanium alloy abutment screw, were tested. A custom load frame with two load cells and associated electronics was used. The threads were not lubricated. All abutment screws were torqued ten times to 25 Ncm. The produced preload values and a force that was proportional to the thread-friction component of the tightening torque were recorded. Results Mean preload values decreased significantly with the number of repetitions (p < 0.0001) from initially 329.9 N ± 33.3 (range 255.7 to 383.9) to 253.7 N ± 36.8 (range 200.1 to 332.5) for the last tightening procedure. The corresponding change in the calculated coefficient of friction was 0.33 ± 0.04 (range 0.28 to 0.43) to 0.44 ± 0.07 (range 0.32 to 0.56). For the thread-friction no corresponding trend for consecutive tightening repetitions could be noticed. Conclusions In the investigated implant–abutment units, repeated use of a coated abutment screw appears to increase the friction of the screw head and thereby decrease the preload. These results indicate that a pre-used coated implant–abutment–screw will fail reaching optimal screw preload.en_GB
dc.description.sponsorshipGefördert durch die Deutsche Forschungsgemeinschaft (DFG) - Projektnummer 491381577de
dc.language.isoengde
dc.rightsCC BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titlePreload and friction in an implant-abutment-screw complex including a carbon-coated titanium alloy abutment screw : an in vitro studyen_GB
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-9436-
jgu.type.contenttypeScientific articlede
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleInternational journal of implant dentistryde
jgu.journal.volume9de
jgu.pages.alternative8de
jgu.publisher.year2023-
jgu.publisher.nameSpringerde
jgu.publisher.placeBerlin u.a.de
jgu.publisher.urihttps://doi.org/10.1186/s40729-023-00473-3de
jgu.publisher.issn2198-4034de
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
jgu.publisher.doi10.1186/s40729-023-00473-3de
jgu.organisation.rorhttps://ror.org/023b0x485-
jgu.subject.dfgLebenswissenschaftende
Appears in collections:DFG-491381577-G

Files in This Item:
  File Description SizeFormat
Thumbnail
preload_and_friction_in_an_im-20230818113652040.pdf1.84 MBAdobe PDFView/Open