Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-8731
Full metadata record
DC FieldValueLanguage
dc.contributor.authorElksne, Eva-
dc.contributor.authorStingl, Julia V.-
dc.contributor.authorSchuster, Alexander K.-
dc.contributor.authorWagner, Felix M.-
dc.contributor.authorHoffmann, Esther M.-
dc.date.accessioned2023-02-02T09:19:02Z-
dc.date.available2023-02-02T09:19:02Z-
dc.date.issued2022-
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/8747-
dc.description.abstractBackground Spectral domain optical coherence tomography (SD-OCT) is a widely applied non-invasive technique for evaluating optic nerve head parameters. The aim of this study was to evaluate the impact of biometric parameters such as the spherical equivalent (SE) and the anterior corneal curvature (ACC) on the peripapillary retinal nerve fiber layer (pRNFL), Bruch’s membrane opening (BMO), and the minimum rim width (MRW) measurements performed by spectral domain optical coherence tomography (SD-OCT) in glaucomatous and healthy eyes. Methods In this cross-sectional, case–control prospective pilot study, the glaucoma group consisted of 50 patients with previously diagnosed and treated glaucoma and one healthy group of 50 subjects. Two consecutive examinations of pRNFL, BMO, and MRW with SD-OCT for every patient were performed without ACC and objective refraction (imaging 1) and with them (imaging 2). Results The interclass correlation coefficient (ICC) reflected high agreement between imaging 1 and imaging 2 in both groups. The ICC in the glaucoma and healthy groups for pRNFL (0.99 vs. 0.98), BMO (0.95 vs. 0.97), and MRW (1.0 vs. 1.0) was comparable. Conclusions Our preliminary data from a small number of eyes showed that the measurements of pRNFL, MRW, and BMO reflected high agreement between both imaging techniques with ACC and objective refraction and without these parameters in subjects with a refractive error up to ± 6.0 diopters. Further studies with participants with higher refractive error are necessary to evaluate the impact of biometric parameters such as SE and ACC on measurements with SD-OCT.en_GB
dc.description.sponsorshipGefördert durch die Deutsche Forschungsgemeinschaft (DFG) - Projektnummer 491381577de
dc.language.isoengde
dc.rightsCC BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleDo biometric parameters improve the quality of optic nerve head measurements with spectral domain optical coherence tomography?en_GB
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-8731-
jgu.type.contenttypeScientific articlede
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleBMC ophthalmologyde
jgu.journal.volume22de
jgu.pages.alternative56de
jgu.publisher.year2022-
jgu.publisher.nameBioMed Centralde
jgu.publisher.placeLondonde
jgu.publisher.issn1471-2415de
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
jgu.publisher.doi10.1186/s12886-022-02281-6de
jgu.organisation.rorhttps://ror.org/023b0x485-
jgu.subject.dfgLebenswissenschaftende
Appears in collections:DFG-491381577-G

Files in This Item:
  File Description SizeFormat
Thumbnail
do_biometric_parameters_impro-20230131160501481.pdf992.37 kBAdobe PDFView/Open