Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-8552
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKriege, Marc-
dc.contributor.authorHilt, J. A.-
dc.contributor.authorDette, Frank-
dc.contributor.authorWittenmeier, Eva-
dc.contributor.authorMeuser, Regina-
dc.contributor.authorStaubnitz, Julia-
dc.contributor.authorMusholt, Thomas J.-
dc.date.accessioned2023-01-11T10:32:48Z-
dc.date.available2023-01-11T10:32:48Z-
dc.date.issued2023-
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/8568-
dc.description.abstractIn thyroid surgery, intra-operative neuromonitoring signals of the recurrent laryngeal nerve can be detected by surface electrodes on a tracheal tube positioned at the vocal fold level. The incidence of difficult tracheal intubation in patients undergoing thyroidectomy for nodular goitre ranges from 5.3% to 20.5%. The aim of this study was to compare videolaryngoscopy with conventional direct laryngoscopy as methods for proper placement of the surface electrode to prevent insufficient intra-operative nerve signal quality. In this prospective randomised trial, adult patients requiring tracheal intubation during thyroid surgery were randomly allocated to two groups of C-MAC® (Macintosh style blade) videolaryngoscope or direct laryngoscopy using the Macintosh laryngoscope. Primary outcome was the incidence of insufficient signal electromyogram amplitude level (< 500 μV) after successful tracheal intubation. A total of 260 (130 per group) participants were analysed. An insufficient signal was more frequent with direct laryngoscopy (35/130, 27%), compared with C-MAC (12/130, 9%, p < 0.001). First-pass tracheal intubation success rate was lower with direct laryngoscopy (86/130 (66%)) compared with the C-MAC (125/130 (96%)) (p < 0.0001). Cormack and Lehane grade ≥ 3 was observed more frequently with direct laryngoscopy (16/130 (12%)), compared with the C-MAC (0/130, (0%)) (p < 0.0001). The results suggest that videolaryngoscopy has an impact on the quality of the initial intra-operative neuromonitoring signal in patients undergoing thyroid surgery, and this technique can provide optimised surface electrode positioning.en_GB
dc.description.sponsorshipGefördert durch die Deutsche Forschungsgemeinschaft (DFG) - Projektnummer 491381577de
dc.language.isoengde
dc.rightsCC BY-NC*
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleImpact of direct laryngoscopy vs. videolaryngoscopy on signal quality of recurrent laryngeal nerve monitoring in thyroid surgery : a randomised parallel group trialen_GB
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-8552-
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleAnaesthesiade
jgu.journal.volume78de
jgu.journal.issue1de
jgu.pages.start55de
jgu.pages.end63de
jgu.publisher.year2023-
jgu.publisher.nameWiley-Blackwellde
jgu.publisher.placeOxford u.ade
jgu.publisher.issn1365-2044de
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
jgu.publisher.doi10.1111/anae.15865de
jgu.organisation.rorhttps://ror.org/023b0x485-
jgu.subject.dfgLebenswissenschaftende
Appears in collections:DFG-491381577-H

Files in This Item:
  File Description SizeFormat
Thumbnail
impact_of_direct_laryngoscopy-20230111111420929.pdf321.06 kBAdobe PDFView/Open