Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-276
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAnadol, Remzi-
dc.contributor.authorSchnitzler, Katharina-
dc.contributor.authorLorenz, Liv-
dc.contributor.authorWeissner, Melissa-
dc.contributor.authorUllrich, Helen-
dc.contributor.authorPolimeni, Alberto-
dc.contributor.authorMünzel, Thomas-
dc.contributor.authorGori, Tommaso-
dc.date.accessioned2019-01-14T13:26:22Z-
dc.date.available2019-01-14T14:26:22Z-
dc.date.issued2018-
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/278-
dc.description.abstractBackground: Diabetes is among the strongest predictors of outcome after coronary artery stenting and the incidence of negative outcomes is still high in this specific group. Data of long-term outcomes comparing diabetic patients with non-diabetic patients treated with bioresorbable scaffolds are still incomplete. This work evaluates the long-term outcomes after implantation of a coronary bioresorbable scaffold (BRS) in diabetic patients compared to non-diabetics. Methods: Patients who received at least one Absorb BRS in the time of May 2012 to December 2014 were enrolled into this single-center registry. Quantitative coronary angiography (QCA) was performed. Results: Six hundred fifty seven patients including 138 patients (21%, mean age 65 ± 11, 78% male) with Diabetes were enrolled. Patients in the diabetic group were significantly older, were more likely to suffer from hypertension and hyperlipidemia and had more often a prior stroke or TIA as well as a reduced renal function (all P < 0.05). The initial stenosis was less severe in the diabetic group (74.8% vs. 79.6%, P = 0.036), but the residual stenosis after BRS implantation exceeded that of the control group (16.7% vs. 13.8%, P = 0.006). History of diabetes had no impact on the incidence of events within one year after BRS implantation. Beyond 1 year, diabetic patients had a higher incidence of cardiovascular death (6.9 vs. 1.4%, HR:5.37 [1.33–21.71], P = 0.001), scaffold restenosis (17.6 vs. 7.8%, HR:3.56 [1.40–9.05], P < 0.0001) and target lesion revascularization (P = 0.016). These results were confirmed in the propensity score analysis. In both diabetics and non-diabetics, there was a strong association (HR:18.6 [4.7–73.3]) between the risk of restenosis and the technique used at implantation; in contrast, the impact of vessel size was more manifest in nondiabetics than in diabetic patients, and an increased risk of restenosis was demonstrated for both large and small vessels. Conclusion: As for metal stents, beyond one year after implantation, diabetes was associated with an increased incidence of scaffold restenosis and related outcomes. This negative impact of diabetes was reset when an optimal implantation technique was used. Keywords: Diabetes, Bioresorbable scaffolds, Coronary artery diseaseen_GB
dc.description.sponsorshipDFG, Open Access-Publizieren Universität Mainz / Universitätsmedizin-
dc.language.isoeng-
dc.rightsCC BYde_DE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleThree-years outcomes of diabetic patients treated with coronary bioresorbable scaffoldsen_GB
dc.typeZeitschriftenaufsatzde_DE
dc.identifier.doihttp://doi.org/10.25358/openscience-276-
jgu.type.dinitypearticle-
jgu.type.versionPublished versionen_GB
jgu.type.resourceText-
jgu.organisation.departmentFB 04 Medizin-
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleBMC cardiovascular disorders-
jgu.journal.volume18-
jgu.pages.alternativeArt. 92-
jgu.publisher.year2018-
jgu.publisher.nameBioMed Central-
jgu.publisher.placeLondon-
jgu.publisher.urihttp://dx.doi.org/10.1186/s12872-018-0811-7-
jgu.publisher.issn1471-2261-
jgu.organisation.placeMainz-
jgu.subject.ddccode610-
opus.date.accessioned2019-01-14T13:26:22Z-
opus.date.modified2019-01-22T10:41:23Z-
opus.date.available2019-01-14T14:26:22-
opus.subject.dfgcode00-000-
opus.organisation.stringFB 04: Medizin: Zentrum für Kardiologiede_DE
opus.organisation.stringFB 04: Medizin: II. Medizinische Klinik und Poliklinikde_DE
opus.identifier.opusid58784-
opus.institute.number0466-
opus.institute.number0426-
opus.metadataonlyfalse-
opus.type.contenttypeKeinede_DE
opus.type.contenttypeNoneen_GB
opus.affiliatedMünzel, Thomas-
opus.affiliatedGori, Tommaso-
jgu.publisher.doi10.1186/s12872-018-0811-7
jgu.organisation.rorhttps://ror.org/023b0x485
Appears in collections:JGU-Publikationen

Files in This Item:
  File Description SizeFormat
Thumbnail
58784.pdf1.07 MBAdobe PDFView/Open