Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-7382
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHasibeder, Astrid-
dc.contributor.authorStein, Pamela-
dc.contributor.authorBrandwijk, Ricardo-
dc.contributor.authorSchild, Hansjörg-
dc.contributor.authorRadsak, Markus-
dc.date.accessioned2022-07-12T09:13:04Z-
dc.date.available2022-07-12T09:13:04Z-
dc.date.issued2015
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/7396-
dc.description.abstractTriggering receptor expressed on myeloid cells (TREM)-1 plays an important role in innate immune responses and is upregulated under infectious as well as non-infectious conditions. In addition, a soluble TREM-1 variant (sTREM-1) is detectable in sera or bronchoalveolar-lavage fluids from patients. Currently, various studies are difficult to compare, since the methods of detection by enzyme-linked immunosorbent assays (ELISA) vary among different research groups. In this study, we compared three different s-TREM-1 specific ELISAs and identified individual assay characteristics finding notable differences in sTREM-1 concentrations in part depending on the employed buffers. Investigating potential confounding factors for sTREM-1 detection, serum heat-inactivation (HI) showed improved recovery compared to non-HI (NHI) serum, reproducible by addition of complement and re-heat-inactivation. Hence we identified complement as a heat-sensitive confounder in some sTREM-1 ELISAs. We conclude that it is difficult to directly compare data of several studies, in particular if different ELISAs are engaged. Immunoassays for research use only are in general hampered by lack of standardization. Further standardization is needed until sTREM-1 ELISA is capable for better reproducibility of studies and clinical application.de_DE
dc.description.sponsorshipDFG, Open Access-Publizieren Universität Mainz / Universitätsmedizinde
dc.language.isoengde
dc.rightsCC BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleEvaluation and validation of the detection of soluble triggering receptor expressed on myeloid cells 1 by enzyme-linked immunosorbent assayfr_FR
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-7382-
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleScientific reportsde
jgu.journal.volume5de
jgu.pages.alternativeArt. 15381de
jgu.publisher.year2015-
jgu.publisher.nameNature Publ. Groupde
jgu.publisher.placeLondonde
jgu.publisher.urihttp://dx.doi.org/10.1038/srep15381de
jgu.publisher.issn2045-2322de
jgu.organisation.placeMainz-
jgu.identifier.pmid26480887
jgu.subject.ddccode610de
opus.date.modified2017-04-25T13:22:39Z
opus.subject.dfgcode00-000
opus.organisation.stringFB 04: Medizin: Institut für Immunologiede_DE
opus.identifier.opusid53329
opus.importsourcepubmed
opus.institute.number0412
opus.metadataonlyfalse
opus.type.contenttypeKeinede_DE
opus.type.contenttypeNoneen_EN
opus.affiliatedSchild, Hansjörg
opus.affiliatedRadsak, Markus
jgu.publisher.doi10.1038/srep15381de
jgu.organisation.rorhttps://ror.org/023b0x485
Appears in collections:DFG-OA-Publizieren (2012 - 2017)

Files in This Item:
  File Description SizeFormat
Thumbnail
evaluation_and_validation_of_-20220710234653630.pdf1.01 MBAdobe PDFView/Open