Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-6700
Full metadata record
DC FieldValueLanguage
dc.contributor.authorThiem, Daniel G. E.-
dc.contributor.authorRömer, Paul-
dc.contributor.authorBlatt, Sebastian-
dc.contributor.authorAl-Nawas, Bilal-
dc.contributor.authorKämmerer, Peer W.-
dc.date.accessioned2022-01-17T10:37:53Z-
dc.date.available2022-01-17T10:37:53Z-
dc.date.issued2021-
dc.identifier.urihttps://openscience.ub.uni-mainz.de/handle/20.500.12030/6710-
dc.description.abstractIn reconstructive surgery, free flap failure, especially in complex osteocutaneous reconstructions, represents a significant clinical burden. Therefore, the aim of the presented study was to assess hyperspectral imaging (HSI) for monitoring of free flaps compared to clinical monitoring. In a prospective, non-randomized clinical study, patients with free flap reconstruction of the oro-maxillofacial-complex were included. Monitoring was assessed clinically and by using hyperspectral imaging (TIVITA™ Tissue-System, DiaspectiveVision GmbH, Pepelow, Germany) to determine tissue-oxygen-saturation [StO2], near-infrared-perfusion-index [NPI], distribution of haemoglobin [THI] and water [TWI], and variance to an adjacent reference area (Δreference). A total of 54 primary and 11 secondary reconstructions were performed including fasciocutaneous and osteocutaneous flaps. Re-exploration was performed in 19 cases. A total of seven complete flap failures occurred, resulting in a 63% salvage rate. Mean time from flap inset to decision making for re-exploration based on clinical assessment was 23.1 ± 21.9 vs. 18.2 ± 19.4 h by the appearance of hyperspectral criteria indicating impaired perfusion (StO2 ≤ 32% OR StO2Δreference > −38% OR NPI ≤ 32.9 OR NPIΔreference ≥ −13.4%) resulting in a difference of 4.8 ± 5 h (p < 0.001). HSI seems able to detect perfusion compromise significantly earlier than clinical monitoring. These findings provide an interpretation aid for clinicians to simplify postoperative flap monitoring.en_GB
dc.description.sponsorshipOpen Access-Publizieren Universität Mainz / Universitätsmedizin Mainzde
dc.language.isoengde
dc.rightsCC BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.ddc610 Medizinde_DE
dc.subject.ddc610 Medical sciencesen_GB
dc.titleNew approach to the old challenge of free flap monitoring : hyperspectral imaging outperforms clinical assessment by earlier detection of perfusion failureen_GB
dc.typeZeitschriftenaufsatzde
dc.identifier.doihttp://doi.org/10.25358/openscience-6700-
jgu.type.dinitypearticleen_GB
jgu.type.versionPublished versionde
jgu.type.resourceTextde
jgu.organisation.departmentFB 04 Medizinde
jgu.organisation.number2700-
jgu.organisation.nameJohannes Gutenberg-Universität Mainz-
jgu.rights.accessrightsopenAccess-
jgu.journal.titleJournal of Personalized Medicinede
jgu.journal.volume11de
jgu.journal.issue11de
jgu.pages.alternative1101de
jgu.publisher.year2021-
jgu.publisher.nameMDPIde
jgu.publisher.placeBaselde
jgu.publisher.urihttps://doi.org/10.3390/jpm11111101de
jgu.publisher.issn2075-4426de
jgu.organisation.placeMainz-
jgu.subject.ddccode610de
jgu.publisher.doi10.3390/jpm11111101
jgu.organisation.rorhttps://ror.org/023b0x485
Appears in collections:JGU-Publikationen

Files in This Item:
  File Description SizeFormat
Thumbnail
new_approach_to_the_old_chall-20220111133923447.pdf3.07 MBAdobe PDFView/Open